The DOI matches its Crossref record.
Vibrational Stark Spectroscopy in Proteins: A Probe and Calibration for Electrostatic Fields
Abstract
We report the first measurement of the vibrational Stark effect in a protein, providing quantitative information on the sensitivity of a vibrational transition to an applied electric field. This can be used to interpret changes in the vibrational frequency that are often observed when amino acids are changed or when a protein undergoes a structural change in terms of the change in the internal or matrix electric field associated with the perturbation. The vibrational Stark effect has been measured for the vibration of CO bound to the heme iron in myoglobin. The vibrational Stark effect is surprisingly large, giving a Stark tuning rate of (2.4/ f ) cm -1 /(MV/cm), where f is the local field correction; this is nearly 4 times larger than for free CO. It is also found that the change in dipole moment is parallel to the transition moment; that is, the change in dipole moment is in the direction perpendicular to the heme plane. Vibrational Stark effect data are also reported as a function of pH, for various mutants, for a modified picket fence porphyrin, and for cytochrome c . The Stark tuning rate is found to be very similar in all cases, indicating that the CO stretch frequency for CO bound to the heme iron is a sensitive and anisotropic local detector of changes in the electrostatic field. This information is used to evaluate electrostatics calculations for heme proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electric Fields and Enzyme Catalysis
Fried, S. D., & Boxer, S. G. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044432 · Cited by 465
Self-citationVibrational Spectroscopic Map, Vibrational Spectroscopy, and Intermolecular Interaction
Baiz, C. R., Błasiak, B., Bredenbeck, J., Cho, M., Choi, J.-H., Corcelli, S. A., Dijkstra, A. G., Feng, C.-J., Garrett-Roe, S., Ge, N.-H., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00813 · Cited by 412
Probing Protein Electrostatics with a Synthetic Fluorescent Amino Acid
Cohen, B. E., McAnaney, T. B., Park, E. S., Jan, Y. N., Boxer, S. G., & Jan, L. Y. (2002) · Science · doi:10.1126/science.1069346 · Cited by 381
Self-citationSuydam, I. T., & Boxer, S. G. (2003) · Biochemistry · doi:10.1021/bi0352926 · Cited by 262
Self-citationGonzalez-Diaz, H., Arrasate, S., Gomez-SanJuan, A., Sotomayor, N., Lete, E., Besada-Porto, L., & Ruso, J. (2013) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026611313140011 · Cited by 101
Metadata
- Authors
- Park, E. S., Andrews, S. S., Hu, R. B., & Boxer, S. G.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-23
- Volume
- 103
- Issue
- 45
- Pages
- 9813-9817
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2098500343
- Cited by
- 216
- References
- 0
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibrational Stark Spectroscopy in Proteins: A Probe and Calibration for Electrostatic Fields. https://app.cochat.ai/papers/10.1021/jp992329g
- The paper
- Park, E. S., Andrews, S. S., Hu, R. B., & Boxer, S. G. (1999). Vibrational Stark Spectroscopy in Proteins: A Probe and Calibration for Electrostatic Fields. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp992329g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.