The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Pepsin−Gold Colloid Conjugates: Preparation, Characterization, and Enzymatic Activity
Abstract
Pepsin−colloidal gold conjugates were prepared by a simple protein-friendly process and the enzymatic activity of the bioconjugates is reported. The pepsin−gold conjugates are obtained by mixing colloidal gold and protein solutions at pH = 3 and, thereafter, centrifugation, washing, and redispersion of the pepsin−gold conjugate material in water. The bioconjugates in solution were characterized by UV−vis spectroscopy, fluorescence spectroscopy, and biocatalytic activity measurements while films of the bioconjugate material obtained by solvent evaporation on suitable substrates were further analyzed by scanning electron microscopy (SEM), energy dispersive analysis of X-rays (EDAX), transmission electron spectroscopy (TEM), Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). While TEM and SEM measurements showed aggregates of the enzyme/colloidal gold conjugates, the intactness of secondary and tertiary structures of the enzyme, as determined by FTIR and fluorescence spectroscopies and confirmed by biocatalytic activity measurements, clearly indicates that the enzyme is stable in its natural state and is possibly stabilized by the colloidal gold particles. The enzyme in the pepsin−Au bioconjugate retained substantial biocatalytic activity and was more stable than the free enzyme in solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE ESTIMATION OF PEPSIN, TRYPSIN, PAPAIN, AND CATHEPSIN WITH HEMOGLOBIN
Anson, M. L. (1938) · Journal of General Physiology · doi:10.1085/jgp.22.1.79 · Cited by 3,272
Optical Absorption Spectra of Nanocrystal Gold Molecules
Alvarez, M. M., Khoury, J. T., Schaaff, T. G., Shafigullin, M. N., Vezmar, I., & Whetten, R. L. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp962922n · Cited by 1,351
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umana, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588
Bastida, Á., Sabuquillo, P., Armisén, P., Fernández‐Lafuente, R., Huguet, J., & Guisan, J. M. (1998) · Biotechnology and Bioengineering · Cited by 531
Caruso, F., Rodda, E., Furlong, D. N., Niikura, K., & Okahata, Y. (1997) · Analytical Chemistry · doi:10.1021/ac961220r · Cited by 436
Mrksich, M., Sigal, G. B., & Whitesides, G. M. (1995) · Langmuir · doi:10.1021/la00011a034 · Cited by 342
Molecular and crystal structures of monoclinic porcine pepsin refined at 1.8A˚resolution
Sielecki, A. R., Fedorov, A. A., Boodhoo, A., Andreeva, N. S., & James, M. N. G. (1990) · Journal of Molecular Biology · doi:10.1016/0022-2836(90)90153-d · Cited by 266
Blueprint for a lipase support: Use of hydrophobic controlled‐pore glasses as model systems
Bosley, J. A., & Clayton, J. C. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260431006 · Cited by 111
[7] Concentration of proteins and removal of solutes
Pohl, T. (1990) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(90)82009-q · Cited by 92
Fang, J., & Knobler, C. M. (1996) · Langmuir · doi:10.1021/la950751s · Cited by 77
Monotonic Behaviors in Semimetals in Strong Magnetic Fields
Chu, H. T. (1972) · Physical review. B, Solid state · doi:10.1103/physrevb.5.4714 · Cited by 47
Stonehuerner, J., Zhao, J., O'Daly, J. P., Crumbliss, A. L., & Henkens, R. W. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85041-8 · Cited by 45
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Extracellular biosynthesis of silver nanoparticles using the fungus Fusarium oxysporum
Ahmad, A., Mukherjee, P., Senapati, S., Mandal, D., Khan, M. I., Kumar, R., & Sastry, M. (2003) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(02)00174-1 · Cited by 1,976
Self-citationSurface modification, functionalization and bioconjugation of colloidal inorganic nanoparticles
Sperling, R. A., & Parak, W. J. (2010) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0273 · Cited by 1,601
Fayaz, A. M., Balaji, K., Girilal, M., Yadav, R., Kalaichelvan, P. T., & Venketesan, R. (2010) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2009.04.006 · Cited by 1,417
Application of Nanoparticles in Electrochemical Sensors and Biosensors
Luo, X., Morrin, A., Killard, A. J., & Smyth, M. R. (2006) · Electroanalysis · doi:10.1002/elan.200503415 · Cited by 1,318
Metadata
- Authors
- Gole, A., Dash, C., Ramakrishnan, V., Sainkar, S. R., Mandale, A. B., Rao, M., & Sastry, M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-03
- Volume
- 17
- Issue
- 5
- Pages
- 1674-1679
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1991491606
- Cited by
- 574
- References
- 12
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.