Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record.

Fluorescent Polyacetylene Thin Film Sensor for Nitroaromatics

Liu, Yao, Mills, Ryan C., Boncella, James M., Schanze, Kirk S.·2001·Langmuir

Abstract

The fluorescence from thin films of poly[1-phenyl-2-(4-trimethylsilylphenyl)ethyne] (PTMSDPA) is strongly quenched by the vapors of a variety of nitroaromatic compounds present at levels ranging from parts-per-million to parts-per-billion in air. The quenching is believed to arise because of the formation of charge-transfer complexes between the electron-poor nitroaromatic quenchers and the electron-rich poly(bis-aryl acetylene). The fluorescence quenching response rate increases as the PTMSPDA film thickness decreases (80 nm → 3 nm) and as the vapor pressure of the nitroaromatic quencher increases. These observations imply that the fluorescence quenching response rate is determined by the rate by which the nitroaromatic compound permeates the PTMSDPA film. The high permeability and large free volume of PTMSDPA are believed to enhance the properties of the material in the application as a thin-film fluorescence sensor for nitroaromatic compounds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la010696p

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Liu, Y., Mills, R. C., Boncella, J. M., & Schanze, K. S.
Venue
Langmuir
Published
2001-10-23
Volume
17
Issue
24
Pages
7452-7455
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2042330258
Cited by
170
References
0
FWCI
0.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.