Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 188

The DOI matches its Crossref record.

Correction of Microrheological Measurements of Soft Samples with Atomic Force Microscopy for the Hydrodynamic Drag on the Cantilever

Alcaraz, J., Buscemi, L., Puig-de-Morales, M., Colchero, J., Baró, A., Navajas, D. · 2002 · Langmuir

Abstract

Force measurements with atomic force microscopy (AFM) in liquid are subjected to the hydrodynamic drag force artifact ( F d ) due to viscous friction of the cantilever with the liquid. This artifact may be especially relevant in microrheological studies of soft samples. Common approaches estimate F d at a certain distance above the sample and subtract its value from the contact force measured on the sample. However, this procedure can underestimate F d at contact. The aim of this work was to assess the effect of the hydrodynamic drag in microrheological AFM measurements of soft samples in liquid at low Reynolds numbers ( Re < 1). Drag forces of water on rectangular and V-shaped cantilevers were measured in noncontact when subjecting the substrate to low-amplitude (35 nm) sinusoidal oscillations at different frequencies (1−200 Hz) and tip−substrate distances ( h ) (0.2−3 μm). F d increased proportionally with the relative velocity ( v ). Moreover, the drag factor b ( h ) defined as F d / v rose when the cantilever approached the substrate. Thus, the hydrodynamic drag exhibited locally a pure viscous behavior. Drag factor dependence on distance was well-fitted ( r 2 ≈ 0.95) by the scaled spherical model b ( h ) = 6πη a eff 2 /( h + h eff ), where η is the viscosity of the liquid, a eff is the effective radius of the cantilever, and h eff is the effective height of the tip. Drag factor at contact was estimated as b (0) = 1.38 × 10 - 6 (rectangular) and 1.55 × 10 - 6 Ns/m (V-shaped) by extrapolating b ( h ) to h = 0. Drag factor measured at 2 μm underestimated b (0) by 30−50%. Thus, correction of the hydrodynamic artifact with drag factor measured a few micrometers above the surface could result in substantial errors in AFM microrheological measurements of soft samples. Our results suggest that drag artifact in contact microrheological measurements under low Re can be accurately estimated by b (0). Precise correction of drag artifact could lead to an improvement in scan speed in contact AFM imaging and in pulling speed in force spectroscopy studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la0110850

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Alcaraz, J., Buscemi, L., Puig-de-Morales, M., Colchero, J., Baró, A., & Navajas, D.
Venue
Langmuir
Published
2002-01-10
Volume
18
Issue
3
Pages
716-721
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2069815010
Cited by
188
References
0
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correction of Microrheological Measurements of Soft Samples with Atomic Force Microscopy for the Hydrodynamic Drag on the Cantilever. https://app.cochat.ai/papers/10.1021/la0110850
The paper
Alcaraz, J., Buscemi, L., Puig-de-Morales, M., Colchero, J., Baró, A., & Navajas, D. (2002). Correction of Microrheological Measurements of Soft Samples with Atomic Force Microscopy for the Hydrodynamic Drag on the Cantilever. Langmuir. https://doi.org/10.1021/la0110850

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.