The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enhanced Performance of an Affinity Biosensor Interface Based on Mixed Self-Assembled Monolayers of Thiols on Gold
Open accessAbstract
An affinity biosensor interface of a biosensor is the interface between the sample and the transducer surface and is therefore of the utmost importance for the general performance of a biosensor. For immunosensor applications the affinity biosensor interface consists of antibodies, which are preferably covalently attached to the transducer surface. In this paper the properties and the enhanced performance of an affinity biosensor interface based on mixed self-assembled monolayers (SAMs) on gold are discussed. Mixed SAMs consist of two different functionalities, which allow attachment of bioreceptor molecules and avoid nonspecific adsorption. In this work, mixed SAMs of thiols with carboxylic and hydroxyl or poly(ethylene glycol) groups are characterized with contact angle measurements, cyclic voltammetry, and grazing-angle Fourier transform infrared spectroscopy. It is found that the various mixed SAMs exhibit acceptable coverage and structural properties. Most importantly, surface plasmon resonance measurements clearly show the enhanced performance of these mixed SAMs with regard to sensitivity, stability, and selectivity compared to commercially available affinity biosensor interfaces. This superiority is experimentally demonstrated by evaluating the amount of immobilized antibodies, the recognition of antigens by the immobilized antibody, and the nonspecific adsorption of IgG molecules on the antibody-coated surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Myszka, D. G. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80157-7 · Cited by 552
Cited by
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Biosensing Based on Light Absorption of Nanoscaled Gold and Silver Particles
Frederix, F., Friedt, J.-M., Choi, K.-H., Laureyn, W., Campitelli, A., Mondelaers, D., Maes, G., & Borghs, G. (2003) · Analytical Chemistry · doi:10.1021/ac0346609 · Cited by 381
Self-citation
Metadata
- Authors
- Frederix, F., Bonroy, K., Laureyn, W., Reekmans, G., Campitelli, A., Dehaen, W., & Maes, G.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-12
- Volume
- 19
- Issue
- 10
- Pages
- 4351-4357
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2041762213
- Cited by
- 178
- References
- 1
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.