Block Copolymer Assemblies with Cross-Link Stabilization: From Single-Component Monolayers to Bilayer Blends with PEO−PLA
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Amphiphilic diblock copolymers containing poly(ethylene oxide) (PEO) and saturated polybutadiene (PBD) hydrophobic chains have been cross-linked in both monolayer and bilayer assemblies. For monolayers, the Langmuir isotherm proves consistent with prior measures of density and compressibility for bilayer vesicles, and the monolayers can be macroscopically transferred as Langmuir−Blodgett films. Since the films are inverted (PBD oriented away from the slide) at the air−water interface, they spontaneously reorganize when immersed in water into wormlike micelles. However, this transition is quenched when the film is stabilized by free radical polymerization. Atomic force microscopy shows a stabilized but pitted film, which allows height measurements that prove consistent with a monolayer. With bilayer vesicles, we investigate several additional aspects of cross-linking. Spatial control of membrane cross-linking on the micrometer-scale is demonstrated by dynamic inflation−deflation of a membrane fixed to the end of a micropipet. Complete polymerization of the bilayer renders vesicles resilient to chloroform solubilization, whereas preblending with a non-cross-linkable diblock copolymer of PEO−polylactic acid, undermines vesicle stability in chloroform−water solutions. The results prove miscibility and stable integration of two disparate block copolymers in a membrane, as well as a first-order scheme for controlled release of encapsulants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross-linked polymersome membranes: Vesicles with broadly adjustable properties
Discher, B. M., Bermudez, H., Hammer, D. A., Discher, D. E., Won, Y.-Y., & Bates, F. S. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp011958z · Cited by 262
Self-citation
Cited by
Discher, D. E., & Ahmed, F. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095838 · Cited by 844
Self-citationSelf-porating polymersomes of peg–pla and peg–pcl: Hydrolysis-triggered controlled release vesicles
Ahmed, F., & Discher, D. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.12.021 · Cited by 667
Self-citationPolymer Architecture and Drug Delivery
Qiu, L. Y., & Bae, Y. H. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-9046-2 · Cited by 604
Polymeric vesicles in biomedical applications
Brinkhuis, R. P., Rutjes, F. P. J. T., & van Hest, J. C. M. (2011) · Polymer Chemistry · doi:10.1039/c1py00061f · Cited by 571
Polymer vesicles in vivo: correlations with PEG molecular weight
Photos, P. J., Bacakova, L., Discher, B., Bates, F. S., & Discher, D. E. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(03)00201-3 · Cited by 527
Self-citation
Metadata
- Authors
- Ahmed, F., Hategan, A., Discher, D. E., & Discher, B. M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-05-16
- Volume
- 19
- Issue
- 16
- Pages
- 6505-6511
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1969535658
- Cited by
- 78
- References
- 1
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.