Preparing Contamination-free Mica Substrates for Surface Characterization, Force Measurements, and Imaging
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Due to its perfect cleavage that provides large areas of molecularly smooth, chemically inert surfaces, mica is the most commonly used natural substrate in measurements with the surface forces apparatus (SFA), in atomic force microscopy (AFM), and in many adsorption studies. However, preparing mica surfaces that are truly clean is not easy since mica is a high-energy surface that readily adsorbs water, organic contaminants, and gases from the atmosphere. Mica can also become charged on cleaving, which makes it prone to picking up oppositely charged particles or mica flakes from the surroundings. High refractive index particles, such as metals, will adhere to mica through van der Waals forces. Recent articles have demonstrated that particle contamination is obtained when inappropriate cutting and handling procedures for the mica are used. In this paper, we show that both particle and other critical contamination is easy to detect and provide proper steps to take during the sample preparation process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluidity of Bound Hydration Layers
Raviv, U., & Klein, J. (2002) · Science · doi:10.1126/science.1074481 · Cited by 721
Fluidity of water confined to subnanometre films
Raviv, U., Laurat, P., & Klein, J. (2001) · Nature · doi:10.1038/35092523 · Cited by 660
Cited by
Boundary slip in Newtonian liquids: a review of experimental studies
Neto, C., Evans, D. R., Bonaccurso, E., Butt, H.-J., & Craig, V. S. J. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/12/r05 · Cited by 1,154
Effects of confinement on freezing and melting
Alba-Simionesco, C., Coasne, B., Dosseh, G., Dudziak, G., Gubbins, K. E., Radhakrishnan, R., & Sliwinska-Bartkowiak, M. (2006) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/18/6/r01 · Cited by 729
Boundary Slip on Smooth Hydrophobic Surfaces: Intrinsic Effects and Possible Artifacts
Cottin-Bizonne, C., Cross, B., Steinberger, A., & Charlaix, E. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.056102 · Cited by 478
Sakuma, H., Otsuki, K., & Kurihara, K. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.046104 · Cited by 141
Surface Forces Apparatus Measurements of Interactions between Rough and Reactive Calcite Surfaces
Dziadkowiec, J., Javadi, S., Bratvold, J. E., Nilsen, O., & Røyne, A. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b00797 · Cited by 52
Metadata
- Authors
- Israelachvili, J. N., Alcantar, N. A., Maeda, N., Mates, T. E., & Ruths, M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-03-23
- Volume
- 20
- Issue
- 9
- Pages
- 3616-3622
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2002067298
- Cited by
- 77
- References
- 2
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparing Contamination-free Mica Substrates for Surface Characterization, Force Measurements, and Imaging. https://app.cochat.ai/papers/10.1021/la0352974
- The paper
- Israelachvili, J. N., Alcantar, N. A., Maeda, N., Mates, T. E., & Ruths, M. (2004). Preparing Contamination-free Mica Substrates for Surface Characterization, Force Measurements, and Imaging. Langmuir. https://doi.org/10.1021/la0352974
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.