CoChat

Synthesis and Characterization of Shell Cross-Linked Micelles with Hydroxy-Functional Coronas: A Pragmatic Alternative to Dendrimers?

Pilon, Laura N., Armes, Steven P., Findlay, Paul, Rannard, Steven P. · 2005 · Langmuir
Cited by 58

The DOI matches its Crossref record.

Abstract

Shell cross-linked (SCL) micelles with hydroxy-functional coronas have been constructed in aqueous solution by exploiting the micellar self-assembly behavior of a new thermoresponsive ABC triblock copolymer. This copolymer was prepared via atom transfer radical polymerization in a convenient one-pot synthesis and comprised a thermoresponsive core-forming poly(propylene oxide) (PPO) block, a cross-linkable central poly(2-(dimethylamino)ethyl methacrylate) (DMA) block, and a hydroxy-functional outer block based on poly(glycerol monomethacrylate) (GMA). DMF GPC analysis confirmed a unimodal molecular weight distribution for the PPO-PDMA-PGMA triblock copolymer precursor, with an M(n) of 12 100 and a polydispersity of approximately 1.26. This copolymer dissolved molecularly in aqueous solution at 5 degrees C but formed micelles with hydroxy-functional coronas above a critical micelle temperature of around 12 degrees C, which corresponded closely to the cloud point of the PPO macroinitiator. Cross-linking of the DMA residues using 1,2-bis(2-iodoethoxy)ethane produced SCL micelles that remained intact at 5 degrees C, i.e., below the cloud point of the core-forming PPO block. Dynamic light scattering studies confirmed that the SCL micelle diameter could be varied depending on the temperature employed for cross-linking: smaller, more compact SCL micelles were formed at higher temperatures, as expected. Since cross-linking involved quaternization of the DMA residues, the SCL micelles acquired cationic surface charge as judged by aqueous electrophoresis studies. These cationic SCL micelles were adsorbed onto near-monodisperse anionic silica sols, which were used as a model colloidal substrate. Thermogravimetric analyses indicated a SCL micelle mass loading of 2.5-4.4%, depending on the silica sol diameter and the initial micelle concentration. Aqueous electrophoresis measurements confirmed that surface charge reversal occurred after adsorption of the SCL micelles, and scanning electron microscopy studies revealed a uniform coating of SCL micelles on the silica particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la047046g

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pilon, L. N., Armes, S. P., Findlay, P., & Rannard, S. P.
Venue
Langmuir
Published
2005-03-17
Volume
21
Issue
9
Pages
3808-3813
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2095411797
Cited by
58
References
0
FWCI
4.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.