Effect of Flow and Surface Conditions on Human Lymphocyte Isolation Using Microfluidic Chambers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Phenotypically pure subpopulations of lymphocytes can provide valuable insights into the immune response to injury and disease. The isolation of these subpopulations presents unique challenges, particularly when preprocessing incubation to attach fluorescent or antibody tags is to be minimized. This paper examines the separation of T and B lymphocytes from mixtures using microfluidic chambers coated with antibodies, focusing on flow conditions and surface chemistry. The adhesion of both cell types decreases as shear stress increases irrespective of the surface chemistry. The incorporation of poly(ethylene glycol) chains along with the antibodies on the chamber surface is shown to significantly improve the reproducibility of cell adhesion and is thus an important part of the overall system design. Furthermore, this technique is shown to be an effective way of isolating highly pure subpopulations of lymphocytes from model mixtures, even when the target cell concentration is low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extra-Large-Pore Zeolites with Two-Dimensional Channels Formed by 14 and 12 Rings
Paillaud, J.-L., Harbuzaru, B., Patarin, J., & Bats, N. (2004) · Science · doi:10.1126/science.1098242 · Cited by 355
Cited by
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Self-citationIsolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Self-citationAptamers from Cell-Based Selection for Bioanalytical Applications
Tan, W., Donovan, M. J., & Jiang, J. (2013) · Chemical Reviews · doi:10.1021/cr300468w · Cited by 649
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Self-citation
Metadata
- Authors
- Murthy, S. K., Sin, A., Tompkins, R. G., & Toner, M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-11-16
- Volume
- 20
- Issue
- 26
- Pages
- 11649-11655
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2055783934
- Cited by
- 144
- References
- 1
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Flow and Surface Conditions on Human Lymphocyte Isolation Using Microfluidic Chambers. https://app.cochat.ai/papers/10.1021/la048047b
- The paper
- Murthy, S. K., Sin, A., Tompkins, R. G., & Toner, M. (2004). Effect of Flow and Surface Conditions on Human Lymphocyte Isolation Using Microfluidic Chambers. Langmuir. https://doi.org/10.1021/la048047b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.