The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Influence of Natural Organic Matter and Ionic Composition on the Kinetics and Structure of Hematite Colloid Aggregation: Implications to Iron Depletion in Estuaries
Abstract
The stability and aggregation behavior of iron oxide colloids in natural waters play an important role in controlling the fate, transport, and bioavailability of trace metals. Time-resolved dynamic light scattering experiments were carried out in a study of the aggregation kinetics and aggregate structure of natural organic matter (NOM) coated hematite colloids and bare hematite colloids. The aggregation behavior was examined over a range of solution chemistries, by adjusting the concentration of the supporting electrolyte-NaCl, CaCl2, or simulated seawater. With the solution pH adjusted so that NOM-coated and bare hematite colloids were at the same zeta potential, we observed a significant difference in colloid stability which results from the stability imparted to the colloids by the adsorbed NOM macromolecules. This enhanced stability of NOM-coated hematite colloids was not observed with CaCl2. Aggregate form expressed as fractal dimension was determined for both NOM-coated and bare hematite aggregates in both NaCl and CaCl2. The fractal dimensions of aggregates formed in the diffusion-limited regime indicate slightly more loosely packed aggregates for bare hematite than theory predicts. For NOM-coated hematite, a small decrease in fractal dimension was observed when the solution composition changed from NaCl to CaCl2. For systems in the reaction-limited regime, the measured fractal dimensions agreed with those in the literature. Colloid aggregation was also studied in synthetic seawater, a mixed cation system to simulate estuarine mixing. Those results describe the important phenomena of iron oxide aggregation and sedimentation in estuaries. When compared to field data from the Mullica Estuary, U.S.A., it is shown that collision efficiency is a good predictor of the iron removal in this natural system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coale, K. H., Johnson, K. S., Fitzwater, S. E., Gordon, R. M., Tanner, S., Chavez, F. P., Ferioli, L., Sakamoto, C., Rogers, P., Millero, F., et al. (1996) · Nature · doi:10.1038/383495a0 · Cited by 1,479
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
French, R. A., Jacobson, A. R., Kim, B., Isley, S. L., Penn, R. L., & Baveye, P. C. (2009) · Environmental Science & Technology · doi:10.1021/es802628n · Cited by 788
Interactions of Dissolved Organic Matter with Natural and Engineered Inorganic Colloids: A Review
Philippe, A., & Schaumann, G. E. (2014) · Environmental Science & Technology · doi:10.1021/es502342r · Cited by 770
Chen, K. L., & Elimelech, M. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2007.01.074 · Cited by 657
Self-citationAdsorption of Humic Acid onto Nanoscale Zerovalent Iron and Its Effect on Arsenic Removal
Giasuddin, A. B. M., Kanel, S. R., & Choi, H. (2007) · Environmental Science & Technology · doi:10.1021/es0616534 · Cited by 498
Metadata
- Authors
- Mylon, S. E., Chen, K. L., & Elimelech, M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-09-09
- Volume
- 20
- Issue
- 21
- Pages
- 9000-9006
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2074577839
- Cited by
- 241
- References
- 1
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.