The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Controlling the Cohesion of Cement Paste
Abstract
The main source of cohesion in cement paste is the nanoparticles of calcium silicate hydrate (C-S-H), which are formed upon the dissolution of the original tricalcium silicate (C(3)S). The interaction between highly charged C-S-H particles in the presence of divalent calcium counterions is strongly attractive because of ion-ion correlations and a negligible entropic repulsion. Traditional double-layer theory based on the Poisson-Boltzmann equation becomes qualitatively incorrect in these systems. Monte Carlo (MC) simulations in the framework of the primitive model of electrolyte solution is then an alternative, where ion-ion correlations are properly included. In addition to divalent calcium counterions, commercial Portland cement contains a variety of other ions (sodium, potassium, sulfate, etc.). The influence of high concentrations of these ionic additives as well as pH on the stability of the final concrete construction is investigated through MC simulations in a grand canonical ensemble. The results show that calcium ions have a strong physical affinity (in opposition to specific chemical adsorption) to the negatively charged silicate particles of interest (C-S-H, C(3)S). This gives concrete surprisingly robust properties, and the cement cohesion is unaffected by the addition of a large variety of additives provided that the calcium concentration and the C-S-H surface charge are high enough. This general phenomenon is also semiquantitatively reproduced from a simple analytical model. The simulations also predict that the affinity of divalent counterions for a highly and oppositely charged surface sometimes is high enough to cause a "charge reversal" of the apparent surface charge in agreement with electrophoretic measurements on both C(3)S and C-S-H particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vitruvius: 'Ten Books on Architecture'
Vitruvius (1999) · Cambridge University Press eBooks · doi:10.1017/cbo9780511840951 · Cited by 128
Cited by
Steric effects in the dynamics of electrolytes at large applied voltages. I. Double-layer charging
Kilic, M. S., Bazant, M. Z., & Ajdari, A. (2007) · Physical Review E · doi:10.1103/physreve.75.021502 · Cited by 815
Modeling and simulation of cement hydration kinetics and microstructure development
Thomas, J. J., Biernacki, J. J., Bullard, J. W., Bishnoi, S., Dolado, J. S., Scherer, G. W., & Luttge, A. (2011) · Cement and Concrete Research · doi:10.1016/j.cemconres.2010.10.004 · Cited by 489
Long range interactions in nanoscale science
French, R. H., Parsegian, V. A., Podgornik, R., Rajter, R. F., Jagota, A., Luo, J., Asthagiri, D., Chaudhury, M. K., Chiang, Y.-M., Granick, S., et al. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.1887 · Cited by 441
Kunther, W., Ferreiro, S., & Skibsted, J. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta06104h · Cited by 440
Improving the structural consistency of C-S-H solid solution thermodynamic models
Kulik, D. A. (2011) · Cement and Concrete Research · doi:10.1016/j.cemconres.2011.01.012 · Cited by 348
Metadata
- Authors
- Jönsson, B., Nonat, A., Labbez, C., Cabane, B., & Wennerström, H.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-09-01
- Volume
- 21
- Issue
- 20
- Pages
- 9211-9221
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1970882122
- Cited by
- 212
- References
- 1
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controlling the Cohesion of Cement Paste. https://app.cochat.ai/papers/10.1021/la051048z
- The paper
- Jönsson, B., Nonat, A., Labbez, C., Cabane, B., & Wennerström, H. (2005). Controlling the Cohesion of Cement Paste. Langmuir. https://doi.org/10.1021/la051048z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.