The DOI matches its Crossref record.
Application of Thiolated Gold Nanoparticles for the Enhancement of Glucose Oxidase Activity
Abstract
Glucose oxidase (GOx) has been covalently immobilized onto chemically synthesized thiolated gold nanoparticles (5-8 nm) via N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The lower value of the Michaelis-Menton constant obtained for the immobilized (3.74 mM) GOx compared with that for the free (5.85 mM) GOx suggests significant enhancement in the activity of GOx attached to thiolated gold nanoparticles. The covalently immobilized GOx thiolated nanoparticles exhibit a response time of 30 s, a shelf life of more than 6 months, and improved tolerance to both pH and temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Potential applications of enzymes immobilized on/in nano materials: A review
Ansari, S. A., & Husain, Q. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.005 · Cited by 1,118
Nanoparticles for biomedical imaging
Nune, S. K., Gunda, P., Thallapally, P. K., Lin, Y.-Y., Laird Forrest, M., & Berkland, C. J. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240903229031 · Cited by 450
Conde, J., Dias, J. T., Grazú, V., Moros, M., Baptista, P. V., & de la Fuente, J. M. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00048 · Cited by 425
Nanomaterials for bio-functionalized electrodes: recent trends
Walcarius, A., Minteer, S. D., Wang, J., Lin, Y., & Merkoçi, A. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20881h · Cited by 366
Wu, P., He, Y., Wang, H.-F., & Yan, X.-P. (2010) · Analytical Chemistry · doi:10.1021/ac902531g · Cited by 345
Waheed, A., Mansha, M., & Ullah, N. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.04.012 · Cited by 305
Arya, S. K., Dey, A., & Bhansali, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.015 · Cited by 118
Self-citationStrategies of enzyme immobilization on nanomatrix supports and their intracellular delivery
Sharifi, M., Karim, A. Y., Mustafa Qadir Nanakali, N., Salihi, A., Aziz, F. M., Hong, J., Khan, R. H., Saboury, A. A., Hasan, A., Abou-Zied, O. K., et al. (2020) · Journal of Biomolecular Structure and Dynamics · doi:10.1080/07391102.2019.1643787 · Cited by 29
Metadata
- Authors
- Pandey, P., Singh, S. P., Arya, S. K., Gupta, V., Datta, M., Singh, S., & Malhotra, B. D.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-01-30
- Volume
- 23
- Issue
- 6
- Pages
- 3333-3337
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2058123640
- Cited by
- 242
- References
- 0
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.