The DOI matches its Crossref record.
pH and Temperature Responsive Polymeric Micelles and Polymersomes by Self-Assembly of Poly[2-(dimethylamino)ethyl methacrylate]-b-Poly(glutamic acid) Double Hydrophilic Block Copolymers
Abstract
The aqueous solution behavior of novel polypeptide-based double hydrophilic block copolymers (DHBCs), namely, poly[2-(dimethylamino)ethyl methacrylate]-b-poly(glutamic acid) (PDMAEMA-b-PGA), exhibiting pH- and temperature-responsiveness is presented using a combination of scattering techniques (light and neutron) and transmission electron microscopy. Close to the isoelectric point (IEP), direct or inverse electrostatic polymersomes are generated by electrostatic interactions developing between the two charged blocks and driving the formation of the hydrophobic membrane of the polymersomes, with the latter being stabilized in water by uncompensated charges. Under basic conditions, that is, when PDMAEMA is uncharged, the thermosensitivity of the DHBCs relates to the lower critical solution temperature (LCST) behavior of PDMAEMA around 40 degrees C. As a consequence, at pH = 11 and below this LCST, free chains of DHBC unimers are evidenced, while above the LCST the hydrophobicity of PDMAEMA drives the self-assembly of the DHBCs in a reversible manner. In this case, spherical polymeric micelles or polymersomes are obtained, depending on the PGA block length. These possibilities of variation in size and shape of morphologies that can be achieved as a function of temperature and/or pH variations open new routes in the development of multiresponsive nanocarriers for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermoresponsive Polymers for Biomedical Applications
Ward, M. A., & Georgiou, T. K. (2011) · Polymers · doi:10.3390/polym3031215 · Cited by 1,158
Functional Block Copolymers: Nanostructured Materials with Emerging Applications
Schacher, F. H., Rupar, P. A., & Manners, I. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200310 · Cited by 694
Karimi, M., Sahandi Zangabad, P., Ghasemi, A., Amiri, M., Bahrami, M., Malekzad, H., Ghahramanzadeh Asl, H., Mahdieh, Z., Bozorgomid, M., Ghasemi, A., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b00371 · Cited by 500
Size-Tunable Strategies for a Tumor Targeted Drug Delivery System
Yu, W., Liu, R., Zhou, Y., & Gao, H. (2020) · ACS Central Science · doi:10.1021/acscentsci.9b01139 · Cited by 489
Engineering Functional Polymer Capsules toward Smart Nanoreactors
Gaitzsch, J., Huang, X., & Voit, B. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00241 · Cited by 397
Metadata
- Authors
- Agut, W., Brûlet, A., Schatz, C., Taton, D., & Lecommandoux, S.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-21
- Volume
- 26
- Issue
- 13
- Pages
- 10546-10554
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2036391463
- Cited by
- 185
- References
- 0
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: pH and Temperature Responsive Polymeric Micelles and Polymersomes by Self-Assembly of Poly[2-(dimethylamino)ethyl methacrylate]-b-Poly(glutamic acid) Double Hydrophilic Block Copolymers. https://app.cochat.ai/papers/10.1021/la1005693
- The paper
- Agut, W., Brûlet, A., Schatz, C., Taton, D., & Lecommandoux, S. (2010). pH and Temperature Responsive Polymeric Micelles and Polymersomes by Self-Assembly of Poly[2-(dimethylamino)ethyl methacrylate]-b-Poly(glutamic acid) Double Hydrophilic Block Copolymers. Langmuir. https://doi.org/10.1021/la1005693
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.