The DOI matches its Crossref record.
Surface Modification of Silicone for Biomedical Applications Requiring Long-Term Antibacterial, Antifouling, and Hemocompatible Properties
Abstract
Silicone has been used for peritoneal dialysis (PD) catheters for several decades. However, bacteria, platelets, proteins, and other biomolecules tend to adhere to its hydrophobic surface, which may lead to PD outflow failure, serious infection, or even death. In this work, a cross-linked poly(poly(ethylene glycol) dimethacrylate) (P(PEGDMA)) polymer layer was covalently grafted on medical-grade silicone surface to improve its antibacterial and antifouling properties. The P(PEGDMA)-grafted silicone (Silicone-g-P(PEGDMA)) substrate reduced the adhesion of Staphylococcus aureus , Escherichia coli , and Staphylococcus epidermidis , as well as 3T3 fibroblast cells by ≥90%. The antibacterial and antifouling properties were preserved after the modified substrate was aged for 30 days in phosphate buffer saline. Further immobilization of a polysulfobetaine polymer, poly((2-(methacryloyloxy)ethyl)dimethyl-(3-sulfopropyl)ammonium hydroxide) (P(DMAPS)), on the Silicone-g-P(PEGDMA) substrate via thiol-ene click reaction leads to enhanced antifouling efficacy and improved hemocompatibility with the preservation of the antibacterial property. Compared to pristine silicone, the so-obtained Silicone-g-P(PEGDMA)-P(DMAPS) substrate reduced the absorption of bovine serum albumin and bovine plasma fibrinogen by ≥80%. It also reduced the number of adherent platelets by ≥90% and significantly prolonged plasma recalcification time. The results indicate that surface grafting with P(PEGDMA) and P(DMAPS) can be potentially useful for the modification of silicone-based PD catheters for long-term applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual-function antibacterial surfaces for biomedical applications
Yu, Q., Wu, Z., & Chen, H. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.01.018 · Cited by 411
Antimicrobial Copper-Based Materials and Coatings: Potential Multifaceted Biomedical Applications
Mitra, D., Kang, E.-T., & Neoh, K. G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17815 · Cited by 322
Self-citationWang, B., Ye, Z., Xu, Q., Liu, H., Lin, Q., Chen, H., & Nan, K. (2016) · Biomaterials Science · doi:10.1039/c6bm00587j · Cited by 61
Retracted
Metadata
- Authors
- Li, M., Neoh, K. G., Xu, L. Q., Wang, R., Kang, E.-T., Lau, T., Olszyna, D. P., & Chiong, E.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-11-12
- Volume
- 28
- Issue
- 47
- Pages
- 16408-16422
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2323158292
- Cited by
- 165
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Modification of Silicone for Biomedical Applications Requiring Long-Term Antibacterial, Antifouling, and Hemocompatible Properties. https://app.cochat.ai/papers/10.1021/la303438t
- The paper
- Li, M., Neoh, K. G., Xu, L. Q., Wang, R., Kang, E.-T., Lau, T., Olszyna, D. P., & Chiong, E. (2012). Surface Modification of Silicone for Biomedical Applications Requiring Long-Term Antibacterial, Antifouling, and Hemocompatible Properties. Langmuir. https://doi.org/10.1021/la303438t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.