Effect of Hydrophilic Defects on Water Transport in MFI Zeolites
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The subnanometer pore structure of zeolites and other microporous materials has been proposed to act as a molecular sieve for various water separation technologies. However, due to the increased interaction between the solid and water in these nanoconfined spaces, it is unclear which type of interface, be it hydrophilic or hydrophobic, offers an advantageous medium for enhancing transport properties. In this work, we probe the role of hydrophilic defects on the transport of water inside the microporous hydrophobic MFI zeolite pore structure via combined sorption and high-pressure infiltration experiments. While the inclusion of defects was observed to increase the amount of water within the zeolite pore network by up to 7 times at the saturation pressure, the diffusivity of this infiltrated water was lowered by up to 2 orders of magnitude in comparison to that of water within the nearly defect-free hydrophobic MFI zeolite. Subsequently, the permeability of water within the more defective MFI zeolite was an order of magnitude lower than that of the nearly defect-free zeolite. The results from these experiments suggest that the intrinsic hydrophobic pore structure of MFI zeolites can facilitate faster water transport due to the decreased attraction between the water and the defect-free surface. While the strong attraction of water to the defects allows for water to infiltrate the porous network at lower pressures, the results suggest that this strong attraction decreases the mobility of the infiltrated water. The insights gained from this study can be utilized to improve the design of future membranes for water desalination and other separation techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anomalously Immobilized Water: A New Water Phase Induced by Confinement in Nanotubes
Mashl, R. J., Joseph, S., Aluru, N. R., & Jakobsson, E. (2003) · Nano Letters · doi:10.1021/nl0340226 · Cited by 447
Cited by
Recent advances in nanomaterials for water protection and monitoring
Das, R., Vecitis, C. D., Schulze, A., Cao, B., Ismail, A. F., Lu, X., Chen, J., & Ramakrishna, S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00921b · Cited by 552
A review on inorganic membranes for desalination and wastewater treatment
Goh, P. S., & Ismail, A. F. (2018) · Desalination · doi:10.1016/j.desal.2017.07.023 · Cited by 537
Song, Y., Xu, N., Liu, G., Qi, H., Zhao, W., Zhu, B., Zhou, L., & Zhu, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01135-y · Cited by 266
Babucci, M., Guntida, A., & Gates, B. C. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00864 · Cited by 235
Factors that Determine Zeolite Stability in Hot Liquid Water
Zhang, L., Chen, K., Chen, B., White, J. L., & Resasco, D. E. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b07398 · Cited by 208
Metadata
- Authors
- Humplik, T., Raj, R., Maroo, S. C., Laoui, T., & Wang, E. N.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-05-29
- Volume
- 30
- Issue
- 22
- Pages
- 6446-6453
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2316555976
- Cited by
- 58
- References
- 1
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.