The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of Graft Densities and Chain Lengths on Separation of Bioactive Compounds by Nanolayered Thermoresponsive Polymer Brush Surfaces
Abstract
We have prepared various poly(N-isopropylacrylamide) (PIPAAm)-grafted silica bead surfaces through surface-initiated atom transfer radical polymerization (ATRP) by changing graft densities and brush chain lengths. The prepared surfaces were characterized by chromatographic analysis using the modified silica beads as chromatographic stationary phases. ATRP initiator (2-(m,p-chloromethylphenyl)ethyltrichlorosilane) density on silica bead surfaces was modulated by changing the feed composition of the self-assembled monolayers (SAMs) of mixed silane coupling agents consisting of ATRP initiator and phenethyltrichlorosilane on the surfaces. IPAAm was then polymerized on SAM-modified silica bead surfaces by ATRP in 2-propanol at 25 degrees C. The chain length of the grafted PIPAAm was controlled by simply changing the ATRP reaction time at constant catalyst concentration. The thermoresponsive surface properties of the PIPAAm-grafted silica beads were investigated by temperature-dependent elution behavior of hydrophobic steroids from the surfaces using Milli-Q water as a mobile phase. On the surfaces grafted with shorter PIPAAm chains, longer retention times for steroids were observed on sparsely grafted PIPAAm surfaces compared to dense PIPAAm brushes at low temperature, because of hydrophobic interactions between the exposed phenethyl groups of SAMs on silica surfaces and steroid molecules. Retention times for steroids on dilute PIPAAm chain columns decreased with temperature similarly to conventional reverse-phase chromatographic modes on octadecyl columns. This effect was due to limited interaction of solutes with the PIPAAm-grafted surfaces. Retention times for steroids on dilute PIPAAm brush surfaces with longer PIPAAm chains became greater above the PIPAAm transition temperature. At low-temperature regions, hydrated and expanded PIPAAm at low temperatures prevented hydrophobic interactions between the phenethyl group of SAMs on the silica bead surfaces and steroid molecules. Retention times for steroids on a dense PIPAAm brush column increased with temperature since solvated polymer segments within the dense brush layer undergo dehydration over a broad range of temperatures. In conclusion, PIPAAm graft density has a crucial influence on the elution behavior of steroids because of the interaction of analytes with silica bead interfaces, and because of the characteristic dehydration of PIPAAm in dense-pack brush surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymer brushes: surface-immobilized macromolecules
Zhao, B., & Brittain, W. J. (2000) · Progress in Polymer Science · doi:10.1016/s0079-6700(00)00012-5 · Cited by 1,628
Cited by
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Zoppe, J. O., Ataman, N. C., Mocny, P., Wang, J., Moraes, J., & Klok, H.-A. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00314 · Cited by 1,046
Krishnamoorthy, M., Hakobyan, S., Ramstedt, M., & Gautrot, J. E. (2014) · Chemical Reviews · doi:10.1021/cr500252u · Cited by 604
Liu, H., Li, Y., Sun, K., Fan, J., Zhang, P., Meng, J., Wang, S., & Jiang, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401000m · Cited by 405
Nagase, K., Yamato, M., Kanazawa, H., & Okano, T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.026 · Cited by 393
Self-citation
Metadata
- Authors
- Nagase, K., Kobayashi, J., Kikuchi, A., Akiyama, Y., Kanazawa, H., & Okano, T.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-12-18
- Volume
- 24
- Issue
- 2
- Pages
- 511-517
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2081819784
- Cited by
- 177
- References
- 1
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.