Combined Use of Atomic Force Microscopy, X-ray Photoelectron Spectroscopy, and Secondary Ion Mass Spectrometry for Cell Surface Analysis
The DOI matches its Crossref record.
Abstract
Understanding the surface properties of microbial cells is a major challenge of current microbiological research and a key to efficiently exploit them in biotechnology. Here, we used three advanced surface analysis techniques with different sensitivity, probing depth, and lateral resolution, that is, in situ atomic force microscopy, X-ray photoelectron spectroscopy, and secondary ion mass spectrometry, to gain insight into the surface properties of the conidia of the human fungal pathogen Aspergillus fumigatus. We show that the native ultrastructure, surface protein and polysaccharide concentrations, and amino acid composition of three mutants affected in hydrophobin production are markedly different from those of the wild-type, thereby providing novel insight into the cell wall architecture of A. fumigatus. The results demonstrate the power of using multiple complementary techniques for probing microbial cell surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface hydrophobin prevents immune recognition of airborne fungal spores
Aimanianda, V., Bayry, J., Bozza, S., Kniemeyer, O., Perruccio, K., Elluru, S. R., Clavaud, C., Paris, S., Brakhage, A. A., Kaveri, S. V., et al. (2009) · Nature · doi:10.1038/nature08264 · Cited by 792
Self-citationHydrophobins: Proteins that self assemble at interfaces
Linder, M. B. (2009) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2009.04.001 · Cited by 379
Advances in Imaging Secondary Ion Mass Spectrometry for Biological Samples
Boxer, S. G., Kraft, M. L., & Weber, P. K. (2009) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133634 · Cited by 308
Towards nanomicrobiology using atomic force microscopy
Dufrêne, Y. F. (2008) · Nature Reviews Microbiology · doi:10.1038/nrmicro1948 · Cited by 259
Self-citationImaging living cells surface and quantifying its properties at high resolution using AFM in QI™ mode
Chopinet, L., Formosa, C., Rols, M. P., Duval, R. E., & Dague, E. (2013) · Micron · doi:10.1016/j.micron.2013.02.003 · Cited by 200
Self-citation
Metadata
- Authors
- Dague, E., Delcorte, A., Latgé, J.-P., & Dufrêne, Y. F.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-01
- Volume
- 24
- Issue
- 7
- Pages
- 2955-2959
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1983883669
- Cited by
- 51
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Use of Atomic Force Microscopy, X-ray Photoelectron Spectroscopy, and Secondary Ion Mass Spectrometry for Cell Surface Analysis. https://app.cochat.ai/papers/10.1021/la703741y
- The paper
- Dague, E., Delcorte, A., Latgé, J.-P., & Dufrêne, Y. F. (2008). Combined Use of Atomic Force Microscopy, X-ray Photoelectron Spectroscopy, and Secondary Ion Mass Spectrometry for Cell Surface Analysis. Langmuir. https://doi.org/10.1021/la703741y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.