Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record.

Quantification of Water and Silanol Species on Various Silicas by Coupling IR Spectroscopy and in-Situ Thermogravimetry

Open access
Gallas, Jean-Paul, Goupil, Jean-Michel, Vimont, Alexandre, Lavalley, Jean-Claude, Gil, Barbara, Gilson, Jean-Pierre, Miserque, Olivier·2009·Langmuir

Abstract

Five silica samples (four precipitated silicas provided by commercial suppliers and one with the MCM-41 structure) have been studied by infrared spectroscopy and by a homemade thermogravimetry-infrared spectrum (TG-IR) setup. The silanol amount, accessibility to water, and different alcohols, and the affinity to water of these various silicas were compared and quantified. TG-IR measurements allowed the precise determination of the integrated molar absorption coefficient of the (nu+delta)OH band, epsilon(nu+delta)OH=(0.16+/-0.01) cm micromol(-1). It is independent of the sample origin and the concentration of silanol groups on silicas. For the precipitated dried samples evacuated at room temperature, the silanol concentration COH varies between 3.6 and 7.0 mmol g(-1). It is 5.3 mmol g(-1) in the case of the MCM-41 sample. Exchange experiments with D2O, followed by back-exchanges with different alcohols (methanol, propan-2-ol, 2-methyl-propan-2-ol, and 3-ethyl-pentan-3-ol) have been followed by infrared spectroscopy. All of the silanols of the MCM-41 sample are accessible to water and alcohol molecules. By contrast, about 20% of the silanols in precipitated samples are not exchanged by D2O (internal silanols). Accessibility decreases with alcohol size; the main effect is relative to methanol. Taking into account the sample specific surface areas and the silanol accessibility to D2O, the surface silanol density of precipitated silicas is close to 8 OH per nm2, at maximum coverage. At variance, the silanol surface density of the MCM silica is much lower, 4 OH per nm2. The TG-IR setup has also been used to determine the amount of water adsorbed on silicas through the intensity of the deltaH2O band. It varies linearly with the concentration of adsorbed water, whatever the silica sample. The integrated molar absorption coefficient of two bands, epsilondeltaH2O=(1.53+/-0.03) cm micromol(-1) and epsilon(nu+delta)H2O=(0.22+/-0.01) cm micromol(-1), have been determined. The number of H2O molecules adsorbed per nm2 has been compared on the five samples under an equilibrium pressure of 13 hPa at room temperature. Taking into account the number of silanols accessible to D2O for each sample, the silica-water affinity has been defined by the H2O/(SiOHsurf) ratio. It is close to 0.8-0.9 for the precipitated samples but lower (0.7) in the case of the MCM one. This result is explained by the more important amount of isolated silanol groups presented by this sample.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la802688w

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 251

Metadata

Authors
Gallas, J.-P., Goupil, J.-M., Vimont, A., Lavalley, J.-C., Gil, B., Gilson, J.-P., & Miserque, O.
Venue
Langmuir
Published
2009-04-23
Volume
25
Issue
10
Pages
5825-5834
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2058629929
Cited by
251
References
0
FWCI
4.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Water and Silanol Species on Various Silicas by Coupling IR Spectroscopy and in-Situ Thermogravimetry. https://app.cochat.ai/papers/10.1021/la802688w
The paper
Gallas, J.-P., Goupil, J.-M., Vimont, A., Lavalley, J.-C., Gil, B., Gilson, J.-P., & Miserque, O. (2009). Quantification of Water and Silanol Species on Various Silicas by Coupling IR Spectroscopy and in-Situ Thermogravimetry. Langmuir. https://doi.org/10.1021/la802688w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.