Flexible Microfluidic Device for Mechanical Property Characterization of Soft Viscoelastic Solids Such as Bacterial Biofilms
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We introduce a flexible microfluidic device to characterize the mechanical properties of soft viscoelastic solids such as bacterial biofilms. In the device, stress is imposed on a test specimen by the application of a fixed pressure to a thin, flexible poly(dimethyl siloxane) (PDMS) membrane that is in contact with the specimen. The stress is applied by pressurizing a microfabricated air channel located above the test area. The strain resulting from the applied stress is quantified by measuring the membrane deflection with a confocal laser scanning microscope. The deflection is governed by the viscoelastic properties of the PDMS membrane and of the test specimen. The relative contributions of the membrane and test material to the measured deformation are quantified by comparing a finite element analysis with an independent (control) measurement of the PDMS membrane mechanical properties. The flexible microfluidic rheometer was used to characterize both the steady-state elastic modulus and the transient strain recoil of two soft materials: gellan gums and bacterial biofilms. The measured linear elastic moduli and viscoelastic relaxation times of gellan gum solutions were in good agreement with the results of conventional mechanical rheometry. The linear Young's moduli of biofilms of Staphylococcus epidermidis and Klebsiella pneumoniae, which could not be measured using conventional methods, were found to be 3.2 and 1.1 kPa, respectively, and the relaxation time of the S. epidermidis biofilm was 13.8 s. Additionally, strain hardening was observed in all the biofilms studied. Finally, design parameters and detection limits of the method show that the device is capable of characterizing soft viscoelastic solids with elastic moduli in the range of 102-105 Pa. The flexible microfluidic rheometer addresses the need for mechanical property characterization of soft viscoelastic solids common in fields such as biomaterials, food, and consumer products. It requires only 200 pL of the test specimen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Biofilm material properties as related to shear-induced deformation and detachment phenomena
Stoodley, P., Cargo, R., Rupp, C. J., Wilson, S., & Klapper, I. (2002) · Journal of Industrial Microbiology and Biotechnology · doi:10.1038/sj.jim.7000282 · Cited by 549
Cited by
Flemming, H.-C., & Wingender, J. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2415 · Cited by 10,137
Microfluidic tools for cell biological research
Velve-Casquillas, G., Le Berre, M., Piel, M., & Tran, P. T. (2010) · Nano Today · doi:10.1016/j.nantod.2009.12.001 · Cited by 359
Mimicking biofilm formation and development: Recent progress in in vitro and in vivo biofilm models
Guzmán-Soto, I., McTiernan, C., Gonzalez-Gomez, M., Ross, A., Gupta, K., Suuronen, E. J., Mah, T.-F., Griffith, M., & Alarcon, E. I. (2021) · iScience · doi:10.1016/j.isci.2021.102443 · Cited by 309
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Wilking, J. N., Angelini, T. E., Seminara, A., Brenner, M. P., & Weitz, D. A. (2011) · MRS Bulletin · doi:10.1557/mrs.2011.71 · Cited by 265
Laminar flow around corners triggers the formation of biofilm streamers
Rusconi, R., Lecuyer, S., Guglielmini, L., & Stone, H. A. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0096 · Cited by 212
“Several studies have shown that biofilms behave as viscoelastic polymer materials, with relaxation times on the order of seconds or minutes (Shaw et al. 2004; Hohne et al. 2009), which means that on a time scale of a few hours a streamer can be considered essentially as a viscous fluid.”
BackgroundElongational rheology of bacterial biofilms in situ
Grumbein, S., Werb, M., Opitz, M., & Lieleg, O. (2016) · Journal of Rheology · doi:10.1122/1.4958667 · Cited by 19
New Technologies for Studying Biofilms
Franklin, M. J., Chang, C., Akiyama, T., & Bothner, B. (2015) · Microbial Biofilms · doi:10.1128/9781555817466.ch1 · Cited by 11
Metadata
- Authors
- Hohne, D. N., Younger, J. G., & Solomon, M. J.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-16
- Volume
- 25
- Issue
- 13
- Pages
- 7743-7751
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2011469955
- Cited by
- 118
- References
- 2
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.