CoChat

Poly(oligo(ethylene glycol)acrylamide) Brushes by Surface Initiated Polymerization: Effect of Macromonomer Chain Length on Brush Growth and Protein Adsorption from Blood Plasma

Kizhakkedathu, Jayachandran N., Janzen, Johan, Le, Yevgeniya, Kainthan, Rajesh K., Brooks, Donald E. · 2009 · Langmuir
Cited by 81

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Three hydrolytically stable polyethyleneglycol (PEG)-based N-substituted acrylamide macromonomers, methoxypolyethyleneglycol (350) acrylamide (MPEG350Am) methoxypolyethyleneglycol (750) acrylamide(MPEG750Am) and methoxypolyethyleneglycol (2000)acrylamide (MPEG2000Am) with increasing PEG chain length were synthesized. Surface-initiated aqueous atom transfer radical polymerization (ATRP) using CuCl/1,1,4,7,10,10-hexamethyl triethylene tetramine (HMTETA) catalyst was utilized to generate dense polymer brushes from these monomers via an ester linker group on the surface of model polystyrene (PS) particles. The molecular weight, hydrodynamic thickness, and graft densities of the grafted polymer layers were controlled by changing the reaction parameters of monomer concentration, addition of Cu(II)Cl2, and sodium chloride. The graft densities of surface-grafted brushes decreased with increasing PEG macromonomer chain length, 350 > 750 >> 2000, under similar experimental conditions. The molecular weight of grafts increased with increase in monomer concentration, and only selected conditions produced narrow distributed polymer chains. The molecular weight of grafted polymer chains differs significantly to those formed in solution. The hydrodynamic thicknesses of the grafted polymer layers were fitted to the Daoud and Cotton model (DCM) for brush height on spherical surfaces. The results show that the size of the pendent groups on the polymer chains has a profound effect on the hydrodynamic thickness of the brush for a given degree of polymerization. The new PEG-based surfaces show good protection against nonspecific protein adsorption from blood plasma compared to the bare surface. Protein adsorption decreased with increasing surface density of grafted polymer chains. Poly(MPEG750Am) brushes were more effective in preventing protein adsorption than poly(MPEG350Am) even at low graft densities, presumably due to the increase in PEG content in the grafted layer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la803690q

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
Kizhakkedathu, J. N., Janzen, J., Le, Y., Kainthan, R. K., & Brooks, D. E.
Venue
Langmuir
Published
2009-02-13
Volume
25
Issue
6
Pages
3794-3801
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W1965785649
Cited by
81
References
2
FWCI
5.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.