Atomic Force Microscopy at Solid−Liquid Interfaces
The DOI matches its Crossref record.
Abstract
An atomic force microscope (AFM) operating in force modulation mode is used to study solvation forces at the interface between a graphite (HOPG) surface and the liquids octamethylcyclotetrasiloxane (OMCTS) and n -dodecanol. Simple analytical models are used that adequately describe the response of the cantilever as the modulation frequency and tip−sample interaction change. The analysis of AFM force curves yields the tip−sample interaction stiffness and damping. Hydrodynamic damping is significant for all the levers used and at present this limits the sensitivity of detecting weak tip−surface damping effects. The main results are: (i) Confinement of liquid between two surfaces can lead to oscillatory structural forces even when one of the surfaces has very high curvature. This could influence topographic images at the atomic level in liquids. In these experiments the typical radius for a sharp AFM tip is measured as R tip ≈ 14 nm. (ii) The effective viscosity increases by ∼4 orders of magnitude for a sharp tip interacting with the OMCTS solvation layers nearest the surface. (iii) The AFM data are compared to published results obtained using the surface force apparatus (SFA). The AFM data for the interaction stiffness and damping are qualitatively similar to the SFA results, but the magnitude of the effects is smaller. This most likely arises from the limited interaction area over which the confined molecules can exhibit cooperative behavior (∼100 nm 2 ). (iv) Oscillatory solvation forces can also be observed with very blunt tips ( R tip ≈ 350 nm), and the data suggest that in this case tip microasperities dominate the tip−sample interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Molecular Structure of Water at Interfaces: Wetting at the Nanometer Scale
Verdaguer, A., Sacha, G. M., Bluhm, H., & Salmeron, M. (2006) · Chemical Reviews · doi:10.1021/cr040376l · Cited by 627
Structure in Confined Room-Temperature Ionic Liquids
Atkin, R., & Warr, G. G. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp067420g · Cited by 500
At the interface: solvation and designing ionic liquids
Hayes, R., Warr, G. G., & Atkin, R. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b920393a · Cited by 418
Martin-Jimenez, D., Chacon, E., Tarazona, P., & Garcia, R. (2016) · Nature Communications · doi:10.1038/ncomms12164 · Cited by 198
Atomic- and Molecular-Resolution Mapping of Solid–Liquid Interfaces by 3D Atomic Force Microscopy
Fukuma, T., & Garcia, R. (2018) · ACS Nano · doi:10.1021/acsnano.8b07216 · Cited by 198
Nanorheology by atomic force microscopy
Li, T.-D., Chiu, H.-C., Ortiz-Young, D., & Riedo, E. (2014) · Review of Scientific Instruments · doi:10.1063/1.4903353 · Cited by 38
Metadata
- Authors
- O'Shea, S. J., & Welland, M. E.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-06-18
- Volume
- 14
- Issue
- 15
- Pages
- 4186-4197
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2018314542
- Cited by
- 126
- References
- 0
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.