Steric Forces Measured with the Atomic Force Microscope at Various Temperatures
Abstract
Steric forces between polymer brushes and atomic force microscope tips were investigated. We studied two systems: polystyrene (PS) grafted to silicon in cyclohexane and poly(ethylene oxide)/poly(methacrylic acid) (PEO/PMAA) diblock copolymer adsorbed with the PMAA block to aluminum oxide in aqueous medium. On approach exponentially decaying repulsive forces were observed in both systems. With a homemade heat stage we could adjust the temperature. Increasing the temperature between 19 and 53 °C led to a linear increase of the decay length for PS in cyclohexane. Also the work required to bring the tip to a certain distance increased roughly linearly with temperature. This supports the view that the repulsion is of entropic origin. At the same time this demonstrates that the temperature dependence of surface forces could be routinely measured. For PEO in water the repulsive force was not significantly affected by a change in temperature. Approaching and retracting parts of force curves measured with PS in cyclohexane were in most cases indistinguishable. In contrast, for PEO in water a significant hysteresis was observed. This might be caused by an escape of polymers underneath the tip of the atomic force microscope. When retracting the tip in some cases the stretching of individual polymers was observed in both systems. Stretching force vs distance curves could be described by a wormlike chain model with typical persistence lengths of 1 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Self-citationA comparison of methods to assess cell mechanical properties
Wu, P.-H., Aroush, D. R.-B., Asnacios, A., Chen, W.-C., Dokukin, M. E., Doss, B. L., Durand-Smet, P., Ekpenyong, A., Guck, J., Guz, N. V., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0015-1 · Cited by 672
Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D. (2005) · Physical Review E · doi:10.1103/physreve.72.021914 · Cited by 421
Tethered polymer chains: surface chemistry and their impact on colloidal and surface properties
Currie, E. P. K., Norde, W., & Cohen Stuart, M. A. (2003) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(02)00061-1 · Cited by 382
Atomic force microscopy detects differences in the surface brush of normal and cancerous cells
Iyer, S., Gaikwad, R. M., Subba-Rao, V., Woodworth, C. D., & Sokolov, I. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.77 · Cited by 352
Guz, N., Dokukin, M., Kalaparthi, V., & Sokolov, I. (2014) · Biophysical Journal · doi:10.1016/j.bpj.2014.06.033 · Cited by 315
Flexible phenylalanine-glycine nucleoporins as entropic barriers to nucleocytoplasmic transport
Lim, R. Y. H., Huang, N.-P., Köser, J., Deng, J., Lau, K. H. A., Schwarz-Herion, K., Fahrenkrog, B., & Aebi, U. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603521103 · Cited by 273
On the molecular basis of fouling resistance
Morra, M. (2000) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856200743869 · Cited by 270
Repulsive Forces and Relaxation on Compression of Entangled, Polydisperse Polystyrene Brushes
Ruths, M., Johannsmann, D., Rühe, J., & Knoll, W. (2000) · Macromolecules · doi:10.1021/ma9920994 · Cited by 80
Self-citation
Metadata
- Authors
- Butt, H.-J., Kappl, M., Mueller, H., Raiteri, R., Meyer, W., & Rühe, J.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-03-01
- Volume
- 15
- Issue
- 7
- Pages
- 2559-2565
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2067835701
- Cited by
- 233
- References
- 0
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.