Oxidation of Carbon Monoxide at a Platinum Film Electrode Studied by Fourier Transform Infrared Spectroscopy with Attenuated Total Reflection Technique
The DOI matches its Crossref record.
Abstract
Fourier transform infrared reflection absorption spectroscopy with the attenuated total reflection technique (ATR-FTIR), coupled with cyclic voltammetry (CV) measurement, is used to observe the oxidation process of adsorbed CO at Pt film sputtered on a silicon prism. The interesting bipolar shape of the linearly bonded CO band is observed at high coverage of CO, although no CO band is included in the reference spectrum. This asymmetric shape is ascribed to Fano resonance. In addition to a linear CO and a bridged CO, a new absorption band, presumably assigned to a carboxyl radical, was detected. This band may be formed by a heterogeneous reaction between adsorbed CO and H 2 O on the Pt surface in the hydrogen adsorption potential region. The adsorbed carboxyl radical was oxidized at a less positive potential than the adsorbed CO, which can be ascribed to a presumable origin for the pre-peak that appeared in a CV reading prior to the oxidation of such a linear or bridged CO. This oxidation led to the rearrangement of CO ad-layers, especially at the high coverage of CO. In the case of the low coverage of CO, the conversion from the bridged CO to the linear CO is ascribed to the potential induced electronic effects of the electrode surface on the adsorption states. A consumption of adsorbed H 2 O and a production of CO 2 were also clearly indicated by the spectroscopy when COOH or CO disappeared from the surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface-enhanced vibrational spectroscopy
Aroca, R., & Rodriguez-Llorente, S. (1997) · Journal of Molecular Structure · doi:10.1016/s0022-2860(96)09489-6 · Cited by 670
Surface-Enhanced Infrared Absorption
Osawa, M. (2007) · Topics in Applied Physics · doi:10.1007/3-540-44552-8_9 · Cited by 409
Lebedeva, N. P., Koper, M. T. M., Feliu, J. M., & van Santen, R. A. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp0204105 · Cited by 408
Miki, A., Ye, S., & Osawa, M. (2002) · Chemical Communications · doi:10.1039/b203392e · Cited by 382
Igarashi, H., Fujino, T., Zhu, Y., Uchida, H., & Watanabe, M. (2001) · Physical Chemistry Chemical Physics · doi:10.1039/b007768m · Cited by 358
Self-citation
Metadata
- Authors
- Zhu, Y., Uchida, H., & Watanabe, M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-09-25
- Volume
- 15
- Issue
- 25
- Pages
- 8757-8764
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1996925671
- Cited by
- 105
- References
- 0
- FWCI
- 9.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxidation of Carbon Monoxide at a Platinum Film Electrode Studied by Fourier Transform Infrared Spectroscopy with Attenuated Total Reflection Technique. https://app.cochat.ai/papers/10.1021/la990835r
- The paper
- Zhu, Y., Uchida, H., & Watanabe, M. (1999). Oxidation of Carbon Monoxide at a Platinum Film Electrode Studied by Fourier Transform Infrared Spectroscopy with Attenuated Total Reflection Technique. Langmuir. https://doi.org/10.1021/la990835r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.