The DOI matches its Crossref record.
Influence of Freely Mobile Grafted Chain Length on Dynamic Properties of Comb-Type Grafted Poly(N-isopropylacrylamide) Hydrogels
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTInfluence of Freely Mobile Grafted Chain Length on Dynamic Properties of Comb-Type Grafted Poly(N-isopropylacrylamide) HydrogelsYuzo Kaneko, Kiyotaka Sakai, Akihiko Kikuchi, Ryo Yoshida, Yasuhisa Sakurai, and Teruo OkanoCite this: Macromolecules 1995, 28, 23, 7717–7723Publication Date (Print):November 1, 1995Publication History Published online1 May 2002Published inissue 1 November 1995https://pubs.acs.org/doi/10.1021/ma00127a018https://doi.org/10.1021/ma00127a018research-articleACS PublicationsRequest reuse permissionsArticle Views1680Altmetric-Citations260LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nano-structured smart hydrogels with rapid response and high elasticity
Xia, L.-W., Xie, R., Ju, X.-J., Wang, W., Chen, Q., & Chu, L.-Y. (2013) · Nature Communications · doi:10.1038/ncomms3226 · Cited by 671
Pulsatile drug release control using hydrogels
Kikuchi, A., & Okano, T. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00243-5 · Cited by 600
Self-citationChung, J. E., Yokoyama, M., Yamato, M., Aoyagi, T., Sakurai, Y., & Okano, T. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00029-2 · Cited by 599
Self-citationDas, A., & Theato, P. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00291 · Cited by 483
Synthesis, characterization and controlled drug release of thermosensitive IPN–PNIPAAm hydrogels
Zhang, X.-Z., Wu, D.-Q., & Chu, C.-C. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.065 · Cited by 470
Metadata
- Authors
- Kaneko, Y., Sakai, K., Kikuchi, A., Yoshida, R., Sakurai, Y., & Okano, T.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-11
- Volume
- 28
- Issue
- 23
- Pages
- 7717-7723
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2019471912
- Cited by
- 277
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Freely Mobile Grafted Chain Length on Dynamic Properties of Comb-Type Grafted Poly(N-isopropylacrylamide) Hydrogels. https://app.cochat.ai/papers/10.1021/ma00127a018
- The paper
- Kaneko, Y., Sakai, K., Kikuchi, A., Yoshida, R., Sakurai, Y., & Okano, T. (1995). Influence of Freely Mobile Grafted Chain Length on Dynamic Properties of Comb-Type Grafted Poly(N-isopropylacrylamide) Hydrogels. Macromolecules. https://doi.org/10.1021/ma00127a018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.