Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 523

The DOI matches its Crossref record.

Layered, Erasable Polymer Multilayers Formed by Hydrogen-Bonded Sequential Self-Assembly

Sukhishvili, Svetlana A., Granick, Steve·2002·Macromolecules

Abstract

Robust multilayers can be formed on solid surfaces, and subsequently destroyed by changing the environmental conditions, by the layer-by-layer sequential assembly of monomolecular films of a polyacid and polybase from aqueous solution. Interlayer hydrogen bonding produces stable multilayers up to the point where altered pH or other environmental stimulus introduces an unacceptably large electrical charge within them. This is demonstrated for the polyacids poly(acrylic acid), PAA, and poly(methacrylic acid), PMAA, and for the polybases poly(vinylpyrrolidone), PVPON, and poly(ethylene oxide), PEO, in D 2 O. The adsorption was quantified by Fourier transform infrared spectroscopy in attenuated total reflection (FTIR-ATR). The ratio between suppressed ionization of the carboxylic groups within the film and their ionization in solution, as directly measured by FTIR-ATR, was used to estimate the fraction of hydrogen-bonded carboxylic groups; this was ∼0.5 in PVPON/PMAA but only ∼0.1 in the PEO/PMAA system, though the dielectric environments appeared to be similar. The critical pH, at which these hydrogen-bonded layers disintegrated, was controlled by a balance of internal ionization and a fraction of carboxylic groups that formed hydrogen bonds with either PVPON or PEO. The critical point was at pH = 6.9 for the PVPON/PMAA films (relatively strong hydrogen bonding), but pH = 4.6 for the PEO/PMAA films (in which a smaller fraction of segments participated in hydrogen bonding). It was even less, pH = 3.6, in the PEO/PAA system, which contained a larger proportion of ionized groups at a given pH owing to the higher acidity of PAA. As a second avenue to control the stability of these multilayer films, ionic strength was varied systematically. In the PEO/PMAA system, the multilayers were stable up to pH = 4.6 in the environment of 10 mM ions (this ionic strength resulted from the buffer solution to control pH), but the multilayers were stable up to higher pH, pH = 5.15, when 0.4 M NaCl was added. The reason is that a higher ionic strength reduced the intensity of electrostatic repulsion between a given number of ionized groups within the multilayer assembly. A slight weakening of stability with decrease of molecular weight was observed (these experiments concerned the PVPON system) as expected from fewer hydrogen bonds per molecule. Finally, experiments with added rhodamine 6G dye showed that dye or drug molecules can be incorporated into such multilayers and then released as needed at preselected conditions a feature that may be used in drug release devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma011346c

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sukhishvili, S. A., & Granick, S.
Venue
Macromolecules
Published
2001-12-05
Volume
35
Issue
1
Pages
301-310
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2006846407
Cited by
523
References
0
FWCI
8.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.