CoChat

Morphology and Melting of Truncated Single Crystals of Linear Polyethylene

Hocquet, S., Dosière, M., Thierry, A., Lotz, B., Koch, M. H. J., Dubreuil, N., Ivanov, D. A. · 2003 · Macromolecules
Cited by 54

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The thickness of (110) and (200) sectors in truncated single crystals of linear polyethylene grown from dilute n -octane solution at 95 °C was measured by atomic force microscopy (AFM) in tapping mode. The (110) sector was found to be 1.1 nm thicker than the (200) sector. This can be explained by a somewhat smaller tilt angle of the chains with respect to the basal plane of the crystal. The tilt of the chains in (110) and (200) sectors, obtained by electron diffraction, is 22° and 30°, respectively. This implies that the length of the stem, i.e., the length of the straight part of the chains between two consecutive folds, is identical in both sectors of the truncated single crystals. The melting of individual LPE truncated single crystals was revisited by AFM. The melting temperatures of the (200) and (110) sectors are 124.9 and 125.9 ± 0.3 °C, respectively. The lamellar thickness distribution calculated from AFM pictures clearly indicates that reorganization into thicker lamellae takes place during heating. The melting of mats of filtration of truncated LPE single crystals has also been investigated by time-resolved small-angle X-ray scattering (SAXS) and differential scanning calorimetry (DSC). The melting curve of LPE single crystals generally exhibits two endotherms. The low and the high melting temperature endotherms are characteristic of single crystals formed from dilute solution and reorganized thicker lamellae during the heating ramp, respectively. Time-resolved SAXS measurements data indicate that two populations of lamellar crystals coexist between 122 and 128 °C. The maximum value observed for the lamellar thickness of the recrystallized material is 30 nm, i.e., twice the initial lamellar thickness of single crystals obtained from dilute solution. There is good agreement between the thicknesses of the crystalline layers obtained from the SAXS data and the values calculated from the Gibbs−Thomson relationship using experimental values of the peak temperature of the two endotherms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma034315l

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hocquet, S., Dosière, M., Thierry, A., Lotz, B., Koch, M. H. J., Dubreuil, N., & Ivanov, D. A.
Venue
Macromolecules
Published
2003-10-07
Volume
36
Issue
22
Pages
8376-8384
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W1983667868
Cited by
54
References
1
FWCI
3.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.