Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Structure, Dispersibility, and Crystallinity of Poly(hydroxybutyrate)/Poly(l-lactic acid) Blends Studied by FT-IR Microspectroscopy and Differential Scanning Calorimetry

Furukawa, Tsuyoshi, Sato, Harumi, Murakami, Rumi, Zhang, Jianming, Duan, Yong-Xin, Noda, Isao, Ochiai, Shukichi, Ozaki, Yukihiro·2005·Macromolecules

Abstract

The present study is aimed at investigating structure, dispersibility, and crystallinity of poly(3-hydroxybutyrate) (PHB) and poly( l -lactic acid) (PLLA) blends by using FT-IR microspectroscopy and differential scanning calorimetry (DSC). Four kinds of PHB/PLLA blends with a PLLA content of 20, 40, 60, and 80 wt % were prepared from chloroform solutions. Micro-IR spectra obtained at different positions of a PHB film are all very similar to each other, suggesting that there is no discernible segregated amorphous and crystalline parts on the PHB film at the resolution scale of micro-IR spectroscopy. On the other hand, the micro-IR spectra of two different positions of a PLLA film, where spherulite structures are observed and they are not observed, are significantly different from each other. PHB and PLLA have characteristic IR marker bands for their crystalline and amorphous components. Therefore, it is possible to explore the structure of each component in the PHB/PLLA blends by using micro-IR spectroscopy. The IR spectra of a position of blends except for the 20/80 blend are similar to that of pure PHB. On the other hand, the IR spectra of another position of the blend consist of the overlap of those of pure PHB and PLLA. For the 20/80 blend, it is difficult to find a position whose spectrum is similar to that of pure PHB. However, a crystalline peak due to the C O stretching band is observed at 1718 cm -1 . This means that PHB crystallizes as very small spherulites or immature spherulites under such blend ratio. DSC curves of the blend show that the heat of crystallization of PHB varies with the blending ratio of PHB and PLLA. The recrystallization peak is detected for PLLA and the 20/80 blend respectively at 106.5 and 88.2 °C. The lowering of recrystallization temperature for the 20/80 blend compared with that of pure PLLA suggests that PHB forms small finely dispersed crystals that may act as nucleation sites of PLLA. The results for the PHB/PLLA blends obtained from IR microspectroscopy indicate that PHB crystallizes in any blends. However, crystalline structures of PHB in the 80/20, 60/40, and 40/60 blends are different from those of the 20/80 blend.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma0504668

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Furukawa, T., Sato, H., Murakami, R., Zhang, J., Duan, Y.-X., Noda, I., Ochiai, S., & Ozaki, Y.
Venue
Macromolecules
Published
2005-06-29
Volume
38
Issue
15
Pages
6445-6454
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2035006802
Cited by
262
References
3
FWCI
3.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.