The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measuring the Modulus of Soft Polymer Networks via a Buckling-Based Metrology
Abstract
We present a new method for measuring the modulus of soft polymer networks ( E < 10 MPa). This metrology utilizes compression-induced buckling of a sensor film applied to the surface of the specimen, where the periodic buckling wavelength, assessed rapidly by laser light diffraction or optical microscopy, yields the modulus of the network specimen. To guide the development of this new technique, we use classical mechanical analysis to calculate the sensitivity of the critical strain and resulting wavelength of the buckling instability to the modulus and thickness of the sensor film as well as the modulus of the soft material being probed. Experimental validation of our technique employed a series of model cross-linked poly(dimethylsiloxane) elastomers. To further demonstrate the versatility of this method, we measure the moduli of a set of pertinent biomaterials, i.e., cross-linked 2-hydroxyethyl methacrylate (HEMA) hydrogels. Using a hydrogel substrate possessing a gradient in the cross-link density, we also show how this metrology can be used to map spatial differences and heterogeneity in modulus within a specimen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Cited by
Finite deformation mechanics in buckled thin films on compliant supports
Jiang, H., Khang, D.-Y., Song, J., Sun, Y., Huang, Y., & Rogers, J. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702927104 · Cited by 721
Polymer Nanocomposites: The “Nano” Effect on Mechanical Properties
Crosby, A. J., & Lee, J. (2007) · Polymer Reviews · doi:10.1080/15583720701271278 · Cited by 620
Surface Wrinkling: A Versatile Platform for Measuring Thin‐Film Properties
Chung, J. Y., Nolte, A. J., & Stafford, C. M. (2011) · Advanced Materials · doi:10.1002/adma.201001759 · Cited by 590
Self-citationWang, Z., Volinsky, A. A., & Gallant, N. D. (2014) · Journal of Applied Polymer Science · doi:10.1002/app.41050 · Cited by 522
Mechanical Buckling: Mechanics, Metrology, and Stretchable Electronics
Khang, D., Rogers, J. A., & Lee, H. H. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801065 · Cited by 404
Wrinkled interfaces: Taking advantage of surface instabilities to pattern polymer surfaces
Rodríguez-Hernández, J. (2015) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.07.008 · Cited by 335
Buckling of a stiff thin film on a compliant substrate in large deformation
Song, J., Jiang, H., Liu, Z. J., Khang, D. Y., Huang, Y., Rogers, J. A., Lu, C., & Koh, C. G. (2008) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2008.01.023 · Cited by 282
Elastic Moduli of Organic Electronic Materials by the Buckling Method
Tahk, D., Lee, H. H., & Khang, D.-Y. (2009) · Macromolecules · doi:10.1021/ma900137k · Cited by 257
Metadata
- Authors
- Wilder, E. A., Guo, S., Lin-Gibson, S., Fasolka, M. J., & Stafford, C. M.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-18
- Volume
- 39
- Issue
- 12
- Pages
- 4138-4143
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2089721082
- Cited by
- 201
- References
- 1
- FWCI
- 42.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.