Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Dielectric and Viscoelastic Responses of Imidazolium-Based Ionomers with Different Counterions and Side Chain Lengths

Choi, U Hyeok, Ye, Yuesheng, Salas de la Cruz, David, Liu, Wenjuan, Winey, Karen I., Elabd, Yossef A., Runt, James, Colby, Ralph H.·2014·Macromolecules

Abstract

A molecular-level understanding of dynamics in imidazolium-based ionomers with different counterions and side chain lengths was investigated using X-ray scattering, oscillatory shear, and dielectric relaxation spectroscopy (DRS). Variations of the counterion size and side chain length lead to changes in glass transition temperature ( T g ), extent of ionic aggregation, and dielectric constant, with consequences for ion transport. A physical model of electrode polarization is used to determine the number density of simultaneously conducting ions and their mobility. Imidazolium-based ionomers with larger counterion and longer side chain have lower T g, resulting in higher ionic conductivity and mobility. The ionic mobility is coupled to ion motions that are directly measured as a second segmental process in DRS, as these are observed to share the same Vogel temperature. Time–temperature superposition (tTS) was applied to create linear viscoelasticity master curves and to investigate the delay in chain motion related to ionic associations. tTS works well for these materials, and the terminal relaxation time increases with decreasing side chain length and smaller counterion size. X-ray scattering confirms the extent of ionic aggregation and helps to rationalize the observed dielectric constants. Larger counterions or longer side chains diminish ionic aggregation, and their ionomers have higher dielectric constants, which agree reasonably with the Onsager prediction at all temperatures studied. Smaller counterions or shorter side chains promote ionic aggregation, and their ionomers have lower dielectric constants, which are directly reflected in the lower content of simultaneously conducting ions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma402263y

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 222

Metadata

Authors
Choi, U. H., Ye, Y., Salas de la Cruz, D., Liu, W., Winey, K. I., Elabd, Y. A., Runt, J., & Colby, R. H.
Venue
Macromolecules
Published
2014-01-06
Volume
47
Issue
2
Pages
777-790
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2328461195
Cited by
222
References
1
FWCI
9.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dielectric and Viscoelastic Responses of Imidazolium-Based Ionomers with Different Counterions and Side Chain Lengths. https://app.cochat.ai/papers/10.1021/ma402263y
The paper
Choi, U. H., Ye, Y., Salas de la Cruz, D., Liu, W., Winey, K. I., Elabd, Y. A., Runt, J., & Colby, R. H. (2014). Dielectric and Viscoelastic Responses of Imidazolium-Based Ionomers with Different Counterions and Side Chain Lengths. Macromolecules. https://doi.org/10.1021/ma402263y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.