The DOI matches its Crossref record.
Poly[(methyl methacrylate)-co-(methacrylic acid)] Microgel Particles: Swelling Control Using pH, Cononsolvency, and Osmotic Deswelling
Abstract
The swelling of poly[(methyl methacrylate)- co -(methacrylic acid)] (PMA-MAA) microgel particles (prepared using 17 mol % MAA) dispersed in water can be controlled by pH adjustment, addition of alkanols, and addition of water soluble homopolymer. Transmission electron microscopy revealed two-dimensional order for PMA-MAA particles deposited on a grid from alkaline solution. The swelling of the microgel particles was studied by means of photon correlation spectroscopy. The stability of the particles was investigated using turbidity−wavelength measurements; flocculation occurred when the pH was less than 6. A buffer (NaHCO 3 /NaOH) was employed to stabilize the pH of the PMA-MAA dispersions at about pH = 10. The hydrodynamic diameter of the PMA-MAA particles is sensitive to pH with a maximum at about pH = 8. PMA-MAA microgel particles deswell upon addition of an alcohol (methanol or 2-propanol) or poly(ethylene glycol) (PEG). Poly( N -isopropylacrylamide) (PNP) microgel particles also deswell in aqueous alcohol solutions. Re-entrant swelling was observed for PMA-MAA and PNP particles when the volume fraction of alcohol exceeded 0.4. The swelling behavior of PMA-MAA and PNP in water−alcohol solvents is attributed to cononsolvency effects. Incompatibility of PEG and PMA-MAA is suggested as the most likely cause for the osmotic deswelling observed upon addition of PMA-MAA particles to aqueous PEG solution. Comparison of the swelling properties of PMA-MAA to those of PNP and literature data suggests that PMA-MAA microgel particles behave as weakly charged networks. Moreover, the comparison reveals that microgel particles and macrogels exhibit important differences in swelling behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kocak, G., Tuncer, C., & Bütün, V. (2017) · Polymer Chemistry · doi:10.1039/c6py01872f · Cited by 1,189
Microgel particles as model colloids: theory, properties and applications
Saunders, B. R., & Vincent, B. (1999) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(98)00071-2 · Cited by 950
Self-citationNanosized cationic hydrogels for drug delivery: preparation, properties and interactions with cells
Vinogradov, S. V., Bronich, T. K., & Kabanov, A. V. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00245-9 · Cited by 775
pH-Responsive polymers: synthesis, properties and applications
Dai, S., Ravi, P., & Tam, K. C. (2008) · Soft Matter · doi:10.1039/b714741d · Cited by 693
Kratz, K., Hellweg, T., & Eimer, W. (2000) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(00)00490-8 · Cited by 375
Dai, Y., Ma, P., Cheng, Z., Kang, X., Zhang, X., Hou, Z., Li, C., Yang, D., Zhai, X., & Lin, J. (2012) · ACS Nano · doi:10.1021/nn300303q · Cited by 322
Photoresponsive Surfactants in Microgel Dispersions
Bradley, M., Vincent, B., Warren, N., Eastoe, J., & Vesperinas, A. (2006) · Langmuir · doi:10.1021/la0523053 · Cited by 52
Self-citation
Metadata
- Authors
- Saunders, B. R., Crowther, H. M., & Vincent, B.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-02-01
- Volume
- 30
- Issue
- 3
- Pages
- 482-487
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W1994033579
- Cited by
- 178
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.