CoChat

Release Kinetics Studies of Aromatic Molecules into Water from Block Polymer Micelles

Teng, Yue, Morrison, M. E., Munk, P., Webber, S. E., Procházka, Karel · 1998 · Macromolecules
Cited by 139

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Micelles formed from amphiphilic block copolymers are known to effect aqueous solubilization of hydrophobic molecules. The kinetics of uptake or release can be monitored by fluorescence if the solubilizate is a fluorophore. The primary objective of this paper is the characterization of the release kinetics in aqueous solution of two hydrophobic fluorescent probes (pyrene and phenanthrene) loaded into polymer micelles composed of the following diblock polymers: polystyrene- block -poly(methacrylic acid), poly( tert -butyl acrylate)- block -poly(2-vinylpyridine), poly(2-vinylpyridine)- block -poly(ethylene oxide). Polystyrene latex particles were also studied for comparison. The release process was analyzed by a model of diffusion out of a sphere and the diffusion constants we measure are very small (10 -18 −10 -16 cm 2 /s), depending on the core and probe. An exception is poly(2-vinylpyridine) for which the release was too fast for our measurement technique. Independent measurements of the partition coefficient of the probes between the micelle and water demonstrated that the micelles are very effective at solubilization (partition coefficients from 3 × 10 4 to 3 × 10 5 were obtained, depending on the micelle−probe combination). Consideration of the partition coefficient, fluorescence quenching of the solubilized probe by Tl +, and the release kinetics has suggested a “three-region” model for solubilization of hydrophobic molecules in this class of polymer micelles: (1) The first is the core, which for several of our systems is glassy. Diffusion from a glassy core is very slow. (2) The second is an “inner corona”, composed of the hydrophilic block polymer which may be swollen by water but its ionization, by gain or loss of protons, is suppressed. The important role of the inner corona in solubilization was not appreciated by us in our earlier study of phenanthrene released from two different PS−PMA micelles. In some cases the majority of the solubilized probe appears to be located in this region. (3) Finally, there is an “outer corona” for which the chains are not crowded and which may sustain a significant charge density. Probe molecules solubilized in this region are accessible to the Tl + quencher.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma971721u

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 139

Metadata

Authors
Teng, Y., Morrison, M. E., Munk, P., Webber, S. E., & Procházka, K.
Venue
Macromolecules
Published
1998-05-15
Volume
31
Issue
11
Pages
3578-3587
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W1972670975
Cited by
139
References
2
FWCI
5.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.