Thermal Transport in Au-Core Polymer-Shell Nanoparticles
Abstract
Thermal transport in aqueous suspensions of Au-core polymer-shell nanoparticles is investigated by time-resolved measurements of optical absorption. The addition of an organic cosolvent to the suspension causes the polystyrene component of the polymer shell to swell, and this change in the microstructure of the shell increases the effective thermal conductivity of the shell by a factor of approximately 2. The corresponding time scale for the cooling of the nanoparticle decreases from 200 ps to approximately 100 ps. The threshold concentration of cosolvent that creates the changes in thermal conductivity, 5 vol % tetrahydrofuran in water or 40 vol % N,N-dimethylformamide in water, is identical to the threshold concentrations for producing small shifts in the frequency of the plasmon resonance. Because the maximum fraction of solvent in the polymer shell is less than 20 vol %, the increase in the effective thermal conductivity of the shell cannot be easily explained by contributions to heat transport by the solvent or enhanced alignment of the polystyrene backbone along the radial direction.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
TDTR can also be easily adapted to transient absorption and be exploited to study thermophysical phenomena in nanoparticle solutions, such as the heat diffusion from particles to the surroundings and thermal transport across surfactants.
“TDTR can also be easily adapted to transient absorption and be exploited to study thermophysical phenomena in nanoparticle solutions, such as the heat diffusion from particles to the surroundings and thermal transport across surfactants, 240-243”
From Tutorial: Time-domain thermoreflectance (TDTR) for thermal property characterization of bulk and thin film materials (2018) · cites this paper as [241]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 31 · Cited by 82
- Authors
- Ge, Z., Kang, Y., Taton, T. A., Braun, P. V., & Cahill, D. G.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Ge, Zhenbin
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-01
- Volume
- 5
- Issue
- 3
- Pages
- 531-535
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2131921462
- Cited by
- 82
- References
- 31
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2022: 1 · 2021: 4 · 2020: 1 · 2019: 2 · 2018: 6 · 2017: 4 · 2016: 4 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 9
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Nano Letters (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
- Keywords
- gold nanoparticles, polymer shell, polystyrene, thermal conductivity, heat transport, cosolvents, tetrahydrofuran, dimethylformamide, plasmon resonance, shell microstructure
- MeSH terms
- Gold, Hot Temperature, Kinetics, Materials Testing, Particle Size, Polymers, Thermal Conductivity, Surface Plasmon Resonance, Nanotechnology, Nanotubes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review