The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Macroscopic Tuning of Nanomechanics: Substrate Bending for Reversible Control of Frequency and Quality Factor of Nanostring Resonators
Abstract
We have employed a chip-bending method to exert continuous and reversible control over the tensile stress in doubly clamped nanomechanical beam resonators. Tensile stress is shown to increase the quality factor of both silicon nitride and single-crystal silicon resonators, implying that added tension can be used as a general, material-independent route to increased quality factor. With this direct stretching technique, we demonstrate beam resonators with unprecedented tunability of both frequency and quality factor. Devices can be tuned back and forth between a high and low stress state, with frequency tunability as large as several hundred percent demonstrated. Over this wide range of frequency, quality factor is also tuned by as much as several hundred percent, providing insights into the loss mechanisms in these materials and this class of nanoresonator. Devices with frequencies in the 1-100 MHz range are studied, with quality factor as high as 390,000 achieved at room temperature, for a silicon nitride device with cross-sectional dimensions below 1 microm, operating in a high stress state. This direct stretching technique may prove useful for the identification of loss mechanisms that contribute to the energy balance in nanomechanical resonators, allowing for the development of new designs that would display higher quality factors. Such devices would have the ability to resolve smaller addendum masses and thus allow more sensitive detection and offer the potential for providing access to previously inaccessible dissipation regimes at low temperatures. This technique provides the ability to dramatically tune both frequency and quality factor, enabling future mechanical resonators to be used as variable frequency references as well as variable band-pass filters in signal-processing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved Oxygen Reduction Activity on Pt 3 Ni(111) via Increased Surface Site Availability
Stamenkovic, V. R., Fowler, B., Mun, B. S., Wang, G., Ross, P. N., Lucas, C. A., & Marković, N. M. (2007) · Science · doi:10.1126/science.1135941 · Cited by 4,421
Cited by
Very High Frequency Silicon Nanowire Electromechanical Resonators
Feng, X. L., He, R., Yang, P., & Roukes, M. L. (2007) · Nano Letters · doi:10.1021/nl0706695 · Cited by 401
Metadata
- Authors
- Verbridge, S. S., Shapiro, D. F., Craighead, H. G., & Parpia, J. M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-05-11
- Volume
- 7
- Issue
- 6
- Pages
- 1728-1735
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1993617326
- Cited by
- 198
- References
- 1
- FWCI
- 15.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Macroscopic Tuning of Nanomechanics: Substrate Bending for Reversible Control of Frequency and Quality Factor of Nanostring Resonators. https://app.cochat.ai/papers/10.1021/nl070716t
- The paper
- Verbridge, S. S., Shapiro, D. F., Craighead, H. G., & Parpia, J. M. (2007). Macroscopic Tuning of Nanomechanics: Substrate Bending for Reversible Control of Frequency and Quality Factor of Nanostring Resonators. Nano Letters. https://doi.org/10.1021/nl070716t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.