The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hydrogen Gas Sensing with Networks of Ultrasmall Palladium Nanowires Formed on Filtration Membranes
Abstract
Hydrogen sensors based on single Pd nanowires show promising results in speed, sensitivity, and ultralow power consumption. The utilization of single Pd nanowires, however, face challenges in nanofabrication, manipulation, and achieving ultrasmall transverse dimensions. We report on hydrogen sensors that take advantage of single palladium nanowires in high speed and sensitivity and that can be fabricated conveniently. The sensors are based on networks of ultrasmall (<10 nm) palladium nanowires deposited onto commercially available filtration membranes. We investigated the sensitivities and response times of these sensors as a function of the thickness of the nanowires and also compared them with a continuous reference film. The superior performance of the ultrasmall Pd nanowire network based sensors demonstrates the novelty of our fabrication approach, which can be directly applied to palladium alloy and other hydrogen sensing materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crabtree, G. W., Dresselhaus, M. S., & Buchanan, M. V. (2004) · Physics Today · doi:10.1063/1.1878333 · Cited by 1,610
Cited by
Nanoantenna-enhanced gas sensing in a single tailored nanofocus
Liu, N., Tang, M. L., Hentschel, M., Giessen, H., & Alivisatos, A. P. (2011) · Nature Materials · doi:10.1038/nmat3029 · Cited by 950
Palladium-Based Nanomaterials: Synthesis and Electrochemical Applications
Chen, A., & Ostrom, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00324 · Cited by 879
Nanoporous Palladium Hydride for Electrocatalytic N 2 Reduction under Ambient Conditions
Xu, W., Fan, G., Chen, J., Li, J., Zhang, L., Zhu, S., Su, X., Cheng, F., & Chen, J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201914335 · Cited by 262
Synthesis of Stable Shape-Controlled Catalytically Active β-Palladium Hydride
Zhao, Z., Huang, X., Li, M., Wang, G., Lee, C., Zhu, E., Duan, X., & Huang, Y. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b11543 · Cited by 155
Metadata
- Authors
- Zeng, X. Q., Latimer, M. L., Xiao, Z. L., Panuganti, S., Welp, U., Kwok, W. K., & Xu, T.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-11-29
- Volume
- 11
- Issue
- 1
- Pages
- 262-268
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2061521170
- Cited by
- 238
- References
- 1
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrogen Gas Sensing with Networks of Ultrasmall Palladium Nanowires Formed on Filtration Membranes. https://app.cochat.ai/papers/10.1021/nl103682s
- The paper
- Zeng, X. Q., Latimer, M. L., Xiao, Z. L., Panuganti, S., Welp, U., Kwok, W. K., & Xu, T. (2011). Hydrogen Gas Sensing with Networks of Ultrasmall Palladium Nanowires Formed on Filtration Membranes. Nano Letters. https://doi.org/10.1021/nl103682s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.