The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Three-Dimensional Morphology of Iron Oxide Nanoparticles with Reactive Concave Surfaces. A Compressed Sensing-Electron Tomography (CS-ET) Approach
Open accessAbstract
In this paper, we apply electron tomography (ET) to the study of the three-dimensional (3D) morphology of iron oxide nanoparticles (NPs) with reactive concave surfaces. The ability to determine quantitatively the volume and shape of the NP concavity is essential for understanding the key-lock mechanism responsible for the destabilization of gold nanocrystals within the iron oxide NP concavity. We show that quantitative ET is enhanced greatly by the application of compressed sensing (CS) techniques to the tomographic reconstruction. High-fidelity tomograms using a new CS-ET algorithm reveal with clarity the concavities of the particle and enable 3D nanometrology studies to be undertaken with confidence. In addition, the robust performance of the CS-ET algorithm with undersampled data should allow rapid progress with time-resolved 3D nanoscale studies, 3D atomic resolution imaging, and cryo-tomography of nanoscale cellular structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Identification of Active Gold Nanoclusters on Iron Oxide Supports for CO Oxidation
Herzing, A. A., Kiely, C. J., Carley, A. F., Landon, P., & Hutchings, G. J. (2008) · Science · doi:10.1126/science.1159639 · Cited by 1,530
Cited by
Mourdikoudis, S., Pallares, R. M., & Thanh, N. T. K. (2018) · Nanoscale · doi:10.1039/c8nr02278j · Cited by 2,191
Atomic-scale determination of surface facets in gold nanorods
Goris, B., Bals, S., Van den Broek, W., Carbó-Argibay, E., Gómez-Graña, S., Liz-Marzán, L. M., & Van Tendeloo, G. (2012) · Nature Materials · doi:10.1038/nmat3462 · Cited by 334
Atomic electron tomography: 3D structures without crystals
Miao, J., Ercius, P., & Billinge, S. J. L. (2016) · Science · doi:10.1126/science.aaf2157 · Cited by 319
Compressed sensing electron tomography
Leary, R., Saghi, Z., Midgley, P. A., & Holland, D. J. (2013) · Ultramicroscopy · doi:10.1016/j.ultramic.2013.03.019 · Cited by 281
Self-citation
Metadata
- Authors
- Saghi, Z., Holland, D. J., Leary, R., Falqui, A., Bertoni, G., Sederman, A. J., Gladden, L. F., & Midgley, P. A.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-05
- Volume
- 11
- Issue
- 11
- Pages
- 4666-4673
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2323264224
- Cited by
- 159
- References
- 3
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.