The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
P-Type Polymer-Hybridized High-Performance Piezoelectric Nanogenerators
Abstract
Enhancing the output power of a nanogenerator is essential in applications as a sustainable power source for wireless sensors and microelectronics. We report here a novel approach that greatly enhances piezoelectric power generation by introducing a p-type polymer layer on a piezoelectric semiconducting thin film. Holes at the film surface greatly reduce the piezoelectric potential screening effect caused by free electrons in a piezoelectric semiconducting material. Furthermore, additional carriers from a conducting polymer and a shift in the Fermi level help in increasing the power output. Poly(3-hexylthiophene) (P3HT) was used as a p-type polymer on piezoelectric semiconducting zinc oxide (ZnO) thin film, and phenyl-C(61)-butyric acid methyl ester (PCBM) was added to P3HT to improve carrier transport. The ZnO/P3HT:PCBM-assembled piezoelectric power generator demonstrated 18-fold enhancement in the output voltage and tripled the current, relative to a power generator with ZnO only at a strain of 0.068%. The overall output power density exceeded 0.88 W/cm(3), and the average power conversion efficiency was up to 18%. This high power generation enabled red, green, and blue light-emitting diodes to turn on after only tens of times bending the generator. This approach offers a breakthrough in realizing a high-performance flexible piezoelectric energy harvester for self-powered electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Self-citationFlexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Self-citation
Cited by
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,918
Self-citationLiu, H., Zhong, J., Lee, C., Lee, S.-W., & Lin, L. (2018) · Applied Physics Reviews · doi:10.1063/1.5074184 · Cited by 905
Mahapatra, S. D., Mohapatra, P. C., Aria, A. I., Christie, G., Mishra, Y. K., Hofmann, S., & Thakur, V. K. (2021) · Advanced Science · doi:10.1002/advs.202100864 · Cited by 642
Fiber-Based Generator for Wearable Electronics and Mobile Medication
Zhong, J., Zhang, Y., Zhong, Q., Hu, Q., Hu, B., Wang, Z. L., & Zhou, J. (2014) · ACS Nano · doi:10.1021/nn501732z · Cited by 612
Self-citationRecent Progress on Piezoelectric and Triboelectric Energy Harvesters in Biomedical Systems
Zheng, Q., Shi, B., Li, Z., & Wang, Z. L. (2017) · Advanced Science · doi:10.1002/advs.201700029 · Cited by 566
Self-citation
Metadata
- Authors
- Lee, K. Y., Kumar, B., Seo, J.-S., Kim, K.-H., Sohn, J. I., Cha, S. N., Choi, D., Wang, Z. L., & Kim, S.-W.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-16
- Volume
- 12
- Issue
- 4
- Pages
- 1959-1964
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2098538899
- Cited by
- 218
- References
- 2
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.