The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrasensitive Flexible Graphene Based Field-Effect Transistor (FET)-Type Bioelectronic Nose
Abstract
Rapid and precise discrimination of various odorants is vital to fabricating enhanced sensing devices in the fields of disease diagnostics, food safety, and environmental monitoring. Here, we demonstrate an ultrasensitive and flexible field-effect transistor (FET) olfactory system, namely, a bioelectronic nose (B-nose), based on plasma-treated bilayer graphene conjugated with an olfactory receptor. The stable p- and n-type behaviors from modified bilayer graphene (MBLG) took place after controlled oxygen and ammonia plasma treatments. It was integrated with human olfactory receptors 2AG1 (hOR2AG1: OR), leading to the formation of the liquid-ion gated FET-type platform. ORs bind to the particular odorant amyl butyrate (AB), and their interactions are specific and selective. The B-noses behave as flexible and transparent sensing devices and can recognize a target odorant with single-carbon-atom resolution. The B-noses are ultrasensitive and highly selective toward AB. The minimum detection limit (MDL) is as low as 0.04 fM (10(-15); signal-to-noise: 4.2), and the equilibrium constants of OR-oxygen plasma-treated graphene (OR-OG) and ammonia plasma-treated graphene (-NG) are ca. 3.44 × 10(14) and 1.47 × 10(14) M(-1), respectively. Additionally, the B-noses have long-term stability and excellent mechanical bending durability in flexible systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationUltrafast Graphene Oxide Humidity Sensors
Borini, S., White, R., Wei, D., Astley, M., Haque, S., Spigone, E., Harris, N., Kivioja, J., & Ryhänen, T. (2013) · ACS Nano · doi:10.1021/nn404889b · Cited by 900
Joshi, N., Hayasaka, T., Liu, Y., Liu, H., Oliveira, O. N., & Lin, L. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2750-5 · Cited by 753
Metadata
- Authors
- Park, S. J., Kwon, O. S., Lee, S. H., Song, H. S., Park, T. H., & Jang, J.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-13
- Volume
- 12
- Issue
- 10
- Pages
- 5082-5090
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2046089319
- Cited by
- 339
- References
- 2
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive Flexible Graphene Based Field-Effect Transistor (FET)-Type Bioelectronic Nose. https://app.cochat.ai/papers/10.1021/nl301714x
- The paper
- Park, S. J., Kwon, O. S., Lee, S. H., Song, H. S., Park, T. H., & Jang, J. (2012). Ultrasensitive Flexible Graphene Based Field-Effect Transistor (FET)-Type Bioelectronic Nose. Nano Letters. https://doi.org/10.1021/nl301714x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.