Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Aptamer-Based SERRS Sensor for Thrombin Detection

Open access
Cho, Hansang, Baker, Brian R., Wachsmann-Hogiu, Sebastian, Pagba, Cynthia V., Laurence, Ted A., Lane, Stephen M., Lee, Luke P., Tok, Jeffrey B.-H.·2008·Nano Letters

Abstract

We describe an aptamer-based surface enhanced resonance Raman scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human alpha-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single-step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5'-capped, 3'-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nl802245w

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 200

Metadata

Authors
Cho, H., Baker, B. R., Wachsmann-Hogiu, S., Pagba, C. V., Laurence, T. A., Lane, S. M., Lee, L. P., & Tok, J. B.-H.
Venue
Nano Letters
Published
2008-11-04
Volume
8
Issue
12
Pages
4386-4390
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2077028663
Cited by
200
References
2
FWCI
5.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aptamer-Based SERRS Sensor for Thrombin Detection. https://app.cochat.ai/papers/10.1021/nl802245w
The paper
Cho, H., Baker, B. R., Wachsmann-Hogiu, S., Pagba, C. V., Laurence, T. A., Lane, S. M., Lee, L. P., & Tok, J. B.-H. (2008). Aptamer-Based SERRS Sensor for Thrombin Detection. Nano Letters. https://doi.org/10.1021/nl802245w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.