The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Rapid Sequencing of Individual DNA Molecules in Graphene Nanogaps
Abstract
I propose a technique for reading the base sequence of a single DNA molecule using a graphene nanogap to read the DNA's transverse conductance. Because graphene is a single atom thick, single-base resolution of the conductance is readily obtained. The nonlinear current-voltage characteristic is used to determine the base type independent of nanogap-width variations that cause the current to change by 5 orders of magnitude. The expected sequencing error rate is 0% up to a nanogap width of 1.6 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sequence of the human genome
Venter, J. C., Adams, M. D., Myers, E. W., Li, P. W., Mural, R. J., Sutton, G. G., Smith, H. O., Yandell, M., Evans, C. A., Holt, R. A., et al. (2001) · Science · doi:10.1126/science.1058040 · Cited by 13,909
Berger, C., Song, Z., Li, T., Li, X., Ogbazghi, A. Y., Feng, R., Dai, Z., Marchenkov, A. N., Conrad, E. H., First, P. N., et al. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp040650f · Cited by 3,548
Cited by
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Separation of Hydrogen and Nitrogen Gases with Porous Graphene Membrane
Du, H., Li, J., Zhang, J., Su, G., Li, X., & Zhao, Y. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp206258u · Cited by 382
Metadata
- Authors
- Postma, H. W. C.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-04
- Volume
- 10
- Issue
- 2
- Pages
- 420-425
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2064364774
- Cited by
- 375
- References
- 2
- FWCI
- 22.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.