The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Nitrogen-Doped Carbon Nanotubes: High Electrocatalytic Activity toward the Oxidation of Hydrogen Peroxide and Its Application for Biosensing
Abstract
This study compares the electrocatalytic activity of nitrogen-doped carbon nanotubes (NCNTs) with multiwalled carbon nanotubes (MWCNTs). Results indicate that NCNTs possess a marked electrocatalytic activity toward oxygen reduction reaction (ORR) by an efficient four-electron process in the alkaline condition, while the process of MWCNTs is through a two-electron pathway. Meanwhile, NCNTs show a very attractive electrochemical performance for the redox reaction of hydrogen peroxide (H2O2) and could be employed as a H2O2 sensor at a low potential of +0.3 V. The sensitivity of the NCNT-based biosensor reaches 24.5 microA/mM, more than 87 times that of the MWCNT-based one. Moreover, NCNTs exhibit striking analytical stability and reproducibility, which enables a reliable and sensitive determination of glucose by monitoring H2O2 produced by an enzymatic reaction between glucose oxidase/glucose or choline oxidase/choline at +0.3 V without the help of the electron mediator. The NCNT-based glucose biosensor has a linear range from 2 to 140 microM with an extremely high sensitivity of 14.9 microA/mM, and the detection limit is estimated to be 1.2 microM at a signal-to-noise ratio of 3. The results indicate that the NCNTs are good nanostructured materials for potential application in biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Subsecond dopamine release promotes cocaine seeking
Phillips, P. E. M., Stuber, G. D., Heien, M. L. A. V., Wightman, R. M., & Carelli, R. M. (2003) · Nature · doi:10.1038/nature01476 · Cited by 1,113
Cited by
Wang, T., Zhu, H., Zhuo, J., Zhu, Z., Papakonstantinou, P., Lubarsky, G., Lin, J., & Li, M. (2013) · Analytical Chemistry · doi:10.1021/ac402114c · Cited by 462
Sha, Y., Lou, J., Bai, S., Wu, D., Liu, B., & Ling, Y. (2015) · Materials Research Bulletin · doi:10.1016/j.materresbull.2015.01.015 · Cited by 62
Metadata
- Authors
- Xu, X., Jiang, S., Hu, Z., & Liu, S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06-21
- Volume
- 4
- Issue
- 7
- Pages
- 4292-4298
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2044753610
- Cited by
- 311
- References
- 2
- FWCI
- 23.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nitrogen-Doped Carbon Nanotubes: High Electrocatalytic Activity toward the Oxidation of Hydrogen Peroxide and Its Application for Biosensing. https://app.cochat.ai/papers/10.1021/nn1010057
- The paper
- Xu, X., Jiang, S., Hu, Z., & Liu, S. (2010). Nitrogen-Doped Carbon Nanotubes: High Electrocatalytic Activity toward the Oxidation of Hydrogen Peroxide and Its Application for Biosensing. ACS Nano. https://doi.org/10.1021/nn1010057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.