The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Coating Graphene Paper with 2D-Assembly of Electrocatalytic Nanoparticles: A Modular Approach toward High-Performance Flexible Electrodes
Abstract
The development of flexible electrodes is of considerable current interest because of the increasing demand for modern electronics, portable medical products, and compact energy devices. We report a modular approach to fabricating high-performance flexible electrodes by structurally integrating 2D-assemblies of nanoparticles with freestanding graphene paper. We have shown that the 2D array of gold nanoparticles at oil-water interfaces can be transferred on freestanding graphene oxide paper, leading to a monolayer of densely packed gold nanoparticles of uniform sizes loaded on graphene oxide paper. One major finding is that the postassembly electrochemical reduction of graphene oxide paper restores the ordered structure and electron-transport properties of graphene, and gives rise to robust and biocompatible freestanding electrodes with outstanding electrocatalytic activities, which have been manifested by the sensitive and selective detection of two model analytes: glucose and hydrogen peroxide (H(2)O(2)) secreted by live cells. The modular nature of this approach coupled with recent progress in nanocrystal synthesis and surface engineering opens new possibilities to systematically study the dependence of catalytic performance on the structural parameters and chemical compositions of the nanocrystals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Organic Nonvolatile Memory Transistors for Flexible Sensor Arrays
Sekitani, T., Yokota, T., Zschieschang, U., Klauk, H., Bauer, S., Takeuchi, K., Takamiya, M., Sakurai, T., & Someya, T. (2009) · Science · doi:10.1126/science.1179963 · Cited by 962
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Wang, T., Zhu, H., Zhuo, J., Zhu, Z., Papakonstantinou, P., Lubarsky, G., Lin, J., & Li, M. (2013) · Analytical Chemistry · doi:10.1021/ac402114c · Cited by 462
Flexible graphene devices related to energy conversion and storage
Wang, X., & Shi, G. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03685a · Cited by 373
Chi, K., Zhang, Z., Xi, J., Huang, Y., Xiao, F., Wang, S., & Liu, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am504539k · Cited by 339
Self-citationRecent advances in biosensor technology in assessment of early diabetes biomarkers
Salek-Maghsoudi, A., Vakhshiteh, F., Torabi, R., Hassani, S., Ganjali, M. R., Norouzi, P., Hosseini, M., & Abdollahi, M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.047 · Cited by 174
Metadata
- Authors
- Xiao, F., Song, J., Gao, H., Zan, X., Xu, R., & Duan, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-06
- Volume
- 6
- Issue
- 1
- Pages
- 100-110
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2102541601
- Cited by
- 213
- References
- 1
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.