Flexible FET-Type VEGF Aptasensor Based on Nitrogen-Doped Graphene Converted from Conducting Polymer
Abstract
Graphene-based field-effect transistors (FETs) have been developed rapidly and are currently considered as an alternative for postsilicon electronics. In this study, polypyrrole-converted nitrogen-doped few-layer graphene (PPy-NDFLG) was grown on Cu substrate by chemical vapor deposition combined with vapor deposition polymerization and then transferred onto a flexible substrate. Furthermore, antivascular endothelial growth factor (VEGF) RNA aptamer conjugated PPy-NDFLG was integrated into a liquid-ion gated FET geometry to fabricate a high-performance VEGF aptamer-based sensor. Field-induced high sensitivity was observed for the analyte-binding events, eventually leading to the recognition of the target molecules at an unprecedentedly low concentration (100 fM). Additionally, the aptasensor had excellent reusability, mechanical bendability, and durability in the flexible process. The developed methodology describes, for the first time, the fabrication of N-doped graphene using conducting polymers including heteroatoms in their structures as the carbonization precursor and demonstrates its use in a high-performance, flexible FET-type aptasensor to detect vascular endothelial growth factor as a cancer biomarker.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Heteroatom-doped graphene materials: syntheses, properties and applications
Wang, X., Sun, G., Routh, P., Kim, D.-H., Huang, W., & Chen, P. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00141a · Cited by 1,891
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Punetha, V. D., Rana, S., Yoo, H. J., Chaurasia, A., McLeskey, J. T., Ramasamy, M. S., Sahoo, N. G., & Cho, J. W. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.12.010 · Cited by 656
New Horizons for Diagnostics and Therapeutic Applications of Graphene and Graphene Oxide
Feng, L., Wu, L., & Qu, X. (2013) · Advanced Materials · doi:10.1002/adma.201203229 · Cited by 632
Metadata
- Authors
- Kwon, O. S., Park, S. J., Hong, J.-Y., Han, A.-R., Lee, J. S., Lee, J. S., Oh, J. H., & Jang, J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-17
- Volume
- 6
- Issue
- 2
- Pages
- 1486-1493
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2050949319
- Cited by
- 253
- References
- 2
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible FET-Type VEGF Aptasensor Based on Nitrogen-Doped Graphene Converted from Conducting Polymer. https://app.cochat.ai/papers/10.1021/nn204395n
- The paper
- Kwon, O. S., Park, S. J., Hong, J.-Y., Han, A.-R., Lee, J. S., Lee, J. S., Oh, J. H., & Jang, J. (2012). Flexible FET-Type VEGF Aptasensor Based on Nitrogen-Doped Graphene Converted from Conducting Polymer. ACS Nano. https://doi.org/10.1021/nn204395n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.