Highly Loaded Hemoglobin Spheres as Promising Artificial Oxygen Carriers
The DOI matches its Crossref record.
Abstract
Seeking safe and effective artificial blood substitutes based on hemoglobin (Hb) as oxygen carriers is an important topic. A significant challenge is to enhance the loading content of Hb in a well-defined structure. Here we report a facile and controllable avenue to fabricate Hb spheres with a high loading content by templating decomposable porous CaCO(3) particles in collaboration with covalent layer-by-layer assembly technique. The surface of the Hb spheres was further chemically modified by biocompatible polyethylene glycol to protect and stabilize the system. Multiple characterization techniques were employed to reveal the loading and density of Hb in an individual CaCO(3) particle. The results demonstrate that the strategy developed in this work is effective and flexible for construction of the highly loaded Hb spheres. More importantly, such Hb spheres retain their carrying-releasing oxygen function. It may thus have great potential to develop Hb spheres with highly loaded content as realistic artificial blood substitutes in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reactive oxygen species generating systems meeting challenges of photodynamic cancer therapy
Zhou, Z., Song, J., Nie, L., & Chen, X. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00271d · Cited by 2,098
Innovative Strategies for Hypoxic‐Tumor Photodynamic Therapy
Li, X., Kwon, N., Guo, T., Liu, Z., & Yoon, J. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201805138 · Cited by 1,175
Molecular Assembly of Schiff Base Interactions: Construction and Application
Jia, Y., & Li, J. (2015) · Chemical Reviews · doi:10.1021/cr400559g · Cited by 524
Self-citationPhototherapy in cancer treatment: strategies and challenges
Cai, Y., Chai, T., Nguyen, W., Liu, J., Xiao, E., Ran, X., Ran, Y., Du, D., Chen, W., & Chen, X. (2025) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-025-02140-y · Cited by 453
Recent advances in innovative strategies for enhanced cancer photodynamic therapy
Hu, T., Wang, Z., Shen, W., Liang, R., Yan, D., & Wei, M. (2021) · Theranostics · doi:10.7150/thno.54227 · Cited by 206
“Considering the poor stability and short circulation time of Hb, artificial red blood cells (RBCs) are combined with Hb to conquer the defects of free Hb [99].”
BackgroundXie, Z., Liang, S., Cai, X., Ding, B., Huang, S., Hou, Z., Ma, P., Cheng, Z., & Lin, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b10685 · Cited by 187
Hemoglobin‐Based Nanoarchitectonic Assemblies as Oxygen Carriers
Jia, Y., Duan, L., & Li, J. (2016) · Advanced Materials · doi:10.1002/adma.201502581 · Cited by 186
Self-citationCovalent layer-by-layer films: chemistry, design, and multidisciplinary applications
An, Q., Huang, T., & Shi, F. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00406k · Cited by 176
Red Blood Cell-Mimicking Micromotor for Active Photodynamic Cancer Therapy
Gao, C., Lin, Z., Wang, D., Wu, Z., Xie, H., & He, Q. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07979 · Cited by 173
Li, F., Mei, H., Gao, Y., Xie, X., Nie, H., Li, T., Zhang, H., & Jia, L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.030 · Cited by 152
Mesoporous Silica Nanoparticles with Large Pores for the Encapsulation and Release of Proteins
Tu, J., Boyle, A. L., Friedrich, H., Bomans, P. H. H., Bussmann, J., Sommerdijk, N. A. J. M., Jiskoot, W., & Kros, A. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b11324 · Cited by 143
Qin, S., Xu, Y., Li, H., Chen, H., & Yuan, Z. (2022) · Biomaterials Science · doi:10.1039/d1bm00317h · Cited by 56
Metadata
- Authors
- Duan, L., Yan, X., Wang, A., Jia, Y., & Li, J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-25
- Volume
- 6
- Issue
- 8
- Pages
- 6897-6904
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1985996962
- Cited by
- 117
- References
- 0
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.