Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Simultaneous Size and ζ-Potential Measurements of Individual Nanoparticles in Dispersion Using Size-Tunable Pore Sensors

Kozak, Darby, Anderson, Will, Vogel, Robert, Chen, Shaun, Antaw, Fiach, Trau, Matt·2012·ACS Nano

Abstract

The prospect of characterizing individual nanoparticles, molecules, or DNA base pairs has generated considerable interest in resistive pulse sensing. In addition to size and concentration analysis, this technique also has the capacity to measure the charge density of objects in situations where electrophoretic forces dominate their motion. Here we present a methodology to simultaneously extract, via appropriate theoretical models, the size and ζ-potential of objects from the resistive pulse signal they generate. The methodology was demonstrated using a size-tunable elastic pore sensor to measure a complex "bimodal" suspension composed of two particle sets with different size and charge. Elastically tuning the size of the pore sensor, by stretching the elastic pore membrane, enables a larger sample size range to be analyzed, improves measurement sensitivity, and fine-tunes the forces acting on objects. This methodology represents a new approach for investigating and understanding the fundamental behavior of nanoscale dispersions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn3020322

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kozak, D., Anderson, W., Vogel, R., Chen, S., Antaw, F., & Trau, M.
Venue
ACS Nano
Published
2012-07-25
Volume
6
Issue
8
Pages
6990-6997
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2024037082
Cited by
188
References
0
FWCI
9.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.