The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Lanthanide Coordination Polymer Nanoparticles for Sensing of Mercury(II) by Photoinduced Electron Transfer
Abstract
The metal-organic coordination polymers at the nanoscale have emerged as attractive nanomaterials due to their tunable nature. In this work, we for the first time prepared an adenine-based lanthanide coordination polymer nanoparticle (CPNP) with fluorescence sensing function. This kind of CPNP was composed of adenine, terbium ion (Tb(3+)), and dipicolinic acid (DPA) as an auxiliary linking molecule that can sensitize the fluorescence of Tb(3+). The fluorescence of the CPNPs is very weak due to the existence of photoinduced electron transfer (PET) from adenine to DPA, which prevents the intramolecular energy transfer from DPA to Tb(3+), leading to the quench of fluorescence of the CPNPs. In the presence of Hg(2+), however, significant enhancement in the fluorescence of CPNPs was observed because of the suppression of the PET process by the coordination of Hg(2+) with adenine. As a kind of Hg(2+) nanosensor, the CPNPs exhibit excellent selectivity and ultrahigh sensitivity up to the 0.2 nM detection limit. The CPNPs also possess an approximately millisecond-scale-long fluorescence lifetime due to the inclusion of Tb(3+) ions. We envision that the CPNPs could find great potential applications in ultrasensitive time-resolved fluorometric assays and biomedical imaging in the future owing to their long emission lifetimes, excellent dispersion, and stability in aqueous solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Choice Reviews Online · doi:10.5860/choice.37-0940 · Cited by 14,314
Cited by
Photochemistry and photophysics of MOFs: steps towards MOF-based sensing enhancements
Dolgopolova, E. A., Rice, A. M., Martin, C. R., & Shustova, N. B. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00861a · Cited by 656
Ariya, P. A., Amyot, M., Dastoor, A., Deeds, D., Feinberg, A., Kos, G., Poulain, A., Ryjkov, A., Semeniuk, K., Subir, M., et al. (2015) · Chemical Reviews · doi:10.1021/cr500667e · Cited by 453
Fluorescent and colorimetric sensors for environmental mercury detection
Chen, G., Guo, Z., Zeng, G., & Tang, L. (2015) · The Analyst · doi:10.1039/c5an00389j · Cited by 335
Design and sensing applications of metal–organic framework composites
Lei, J., Qian, R., Ling, P., Cui, L., & Ju, H. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.02.012 · Cited by 332
Moghzi, F., Foroshani, F. Z., Hedayati, Z., Soleimannejad, J., Kateshali, A. F., & Janczak, J. (2025) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2025.136320 · Cited by 3
Metadata
- Authors
- Tan, H., Liu, B., & Chen, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-11-09
- Volume
- 6
- Issue
- 12
- Pages
- 10505-10511
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2321028096
- Cited by
- 261
- References
- 1
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.