The DOI matches its Crossref record.
A Simple Millifluidic Benchtop Reactor System for the High-Throughput Synthesis and Functionalization of Gold Nanoparticles with Different Sizes and Shapes
Abstract
Despite the continuing interest in the applications of functionalized nanomaterials, the controlled and reproducible synthesis of many important functionalized nanoparticles (NPs) above the milligram scale continues to be a significant challenge. The synthesis of functionalized NPs in automated reactors provides a viable approach to circumvent some of the shortcomings of traditional nanomaterial batch syntheses, providing superior control over reagent addition, improved reproducibility, the opportunity to interface real-time product monitoring, and a viable high-throughput synthetic approach. Here, we demonstrate the construction and operation of a simple millifluidic reactor assembled entirely from commercially available components found in almost any chemical laboratory. This reactor facilitates the aqueous gram-scale synthesis of a variety of functionalized gold nanoparticles, including the synthesis of gold nanospheres with tightly controlled core diameters and gold nanorods with controlled aspect ratios between 1.5 and 4.0. The absolute dimensions (i.e., the transverse diameter) of gold nanorods synthesized within the reactor can also be tailored to produce different gold nanorod shapes, including "small" gold nanorods and gold nanocubes. In addition, we show that the reactor can interface with existing purification and monitoring techniques in order to enable the high-throughput functionalization/purification of gold nanorods and real-time monitoring of gold nanoparticle products for quality control. We anticipate that this millifluidic reactor will provide the blueprint for a versatile and portable approach to the gram-scale synthesis of monodisperse, hydrophilically functionalized metal NPs that can be realized in almost any chemistry research laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Progress in Cancer Thermal Therapy Using Gold Nanoparticles
Abadeer, N. S., & Murphy, C. J. (2016) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5b11232 · Cited by 919
Self-citationA “Tips and Tricks” Practical Guide to the Synthesis of Gold Nanorods
Scarabelli, L., Sánchez-Iglesias, A., Pérez-Juste, J., & Liz-Marzán, L. M. (2015) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.5b02123 · Cited by 574
Ziegler, C., Wolf, A., Liu, W., Herrmann, A., Gaponik, N., & Eychmüller, A. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201611552 · Cited by 419
Prakash, J., Sun, S., Swart, H. C., & Gupta, R. K. (2018) · Applied Materials Today · doi:10.1016/j.apmt.2018.02.002 · Cited by 324
Feng, Z. V., Gunsolus, I. L., Qiu, T. A., Hurley, K. R., Nyberg, L. H., Frew, H., Johnson, K. P., Vartanian, A. M., Jacob, L. M., Lohse, S. E., et al. (2015) · Chemical Science · doi:10.1039/c5sc00792e · Cited by 258
Self-citation
Metadata
- Authors
- Lohse, S. E., Eller, J. R., Sivapalan, S. T., Plews, M. R., & Murphy, C. J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-05-07
- Volume
- 7
- Issue
- 5
- Pages
- 4135-4150
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2313049980
- Cited by
- 243
- References
- 0
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.