The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Performance Flexible Graphene Aptasensor for Mercury Detection in Mussels
Abstract
Mercury (Hg) is highly toxic but has been widely used for numerous domestic applications, including thermometers and batteries, for decades, which has led to fatal outcomes due to its accumulation in the human body. Although many types of mercury sensors have been developed to protect the users from Hg, few methodologies exist to analyze Hg(2+) ions in low concentrations in real world samples. Herein, we describe the fabrication and characterization of liquid-ion gated field-effect transistor (FET)-type flexible graphene aptasensor with high sensitivity and selectivity for Hg. The field-induced responses from the graphene aptasensor had excellent sensing performance, and Hg(2+) ions with very low concentration of 10 pM could be detected, which is 2-3 orders of magnitude more sensitive than previously reported mercury sensors using electrochemical systems. Moreover, the aptasensor showed a highly specific response to Hg(2+) ions in mixed solutions. The flexible graphene aptasensor showed a very rapid response, providing a signal in less than 1 s when the Hg(2+) ion concentration was altered. Specificity to Hg(2+) ions was demonstrated in real world samples (in this case samples derived from mussels). The aptasensor was fabricated by transferring chemical vapor deposition (CVD)-grown graphene onto a transparent flexible substrate, and the structure displayed excellent mechanical durability and flexiblility. This graphene-based aptasensor has potential for detecting Hg exposure in human and in the environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Cited by
An Overview of the Development of Flexible Sensors
Han, S., Peng, H., Sun, Q., Venkatesh, S., Chung, K., Lau, S. C., Zhou, Y., & Roy, V. A. L. (2017) · Advanced Materials · doi:10.1002/adma.201700375 · Cited by 771
Chemical sensing with 2D materials
Anichini, C., Czepa, W., Pakulski, D., Aliprandi, A., Ciesielski, A., & Samorì, P. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00417j · Cited by 756
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Sensing at the Surface of Graphene Field‐Effect Transistors
Fu, W., Jiang, L., van Geest, E. P., Lima, L. M. C., & Schneider, G. F. (2017) · Advanced Materials · doi:10.1002/adma.201603610 · Cited by 364
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Wang, L., Wang, X., Wu, Y., Guo, M., Gu, C., Dai, C., Kong, D., Wang, Y., Zhang, C., Qu, D., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00833-7 · Cited by 334
Recent Progress of Self‐Powered Sensing Systems for Wearable Electronics
Lou, Z., Li, L., Wang, L., & Shen, G. (2017) · Small · doi:10.1002/smll.201701791 · Cited by 309
Metadata
- Authors
- An, J. H., Park, S. J., Kwon, O. S., Bae, J., & Jang, J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-02
- Volume
- 7
- Issue
- 12
- Pages
- 10563-10571
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2335087698
- Cited by
- 211
- References
- 1
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.