The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
ZnO Nanowire Arrays on 3D Hierachical Graphene Foam: Biomarker Detection of Parkinson’s Disease
Abstract
We report that vertically aligned ZnO nanowire arrays (ZnO NWAs) were fabricated on 3D graphene foam (GF) and used to selectively detect uric acid (UA), dopamine (DA), and ascorbic acid (AA) by a differential pulse voltammetry method. The optimized ZnO NWA/GF electrode provided a high surface area and high selectivity with a detection limit of 1 nM for UA and DA. The high selectivity in the oxidation potential was explained by the gap difference between the lowest unoccupied and highest occupied molecular orbitals of a biomolecule for a set of given electrodes. This method was further used to detect UA levels in the serum of patients with Parkinson's disease (PD). The UA level was 25% lower in PD patients than in healthy individuals. This finding strongly implies that UA can be used as a biomarker for PD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novoselov, K. S., Fal′ko, V. I., Colombo, L., Gellert, P. R., Schwab, M. G., & Kim, K. (2012) · Nature · doi:10.1038/nature11458 · Cited by 9,251
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Nanowire dye-sensitized solar cells
Law, M., Greene, L. E., Johnson, J. C., Saykally, R., & Yang, P. (2005) · Nature Materials · doi:10.1038/nmat1387 · Cited by 5,332
Chen, Z., Ren, W., Gao, L., Liu, B., Pei, S., & Cheng, H.-M. (2011) · Nature Materials · doi:10.1038/nmat3001 · Cited by 3,834
Uneven Pattern of Dopamine Loss in the Striatum of Patients with Idiopathic Parkinson's Disease
Kish, S. J., Shannak, K., & Hornykiewicz, O. (1988) · New England Journal of Medicine · doi:10.1056/nejm198804073181402 · Cited by 1,953
Biological and chemical sensors based on graphene materials
Liu, Y., Dong, X., & Chen, P. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15270j · Cited by 1,748
Oxidation Resistance of Graphene-Coated Cu and Cu/Ni Alloy
Chen, S., Brown, L., Levendorf, M., Cai, W., Ju, S.-Y., Edgeworth, J., Li, X., Magnuson, C. W., Velamakanni, A., Piner, R. D., et al. (2011) · ACS Nano · doi:10.1021/nn103028d · Cited by 1,374
Flexible graphene-based lithium ion batteries with ultrafast charge and discharge rates
Li, N., Chen, Z., Ren, W., Li, F., & Cheng, H.-M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210072109 · Cited by 794
Sheng, Z.-H., Zheng, X.-Q., Xu, J.-Y., Bao, W.-J., Wang, F.-B., & Xia, X.-H. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.01.030 · Cited by 748
Sun, C.-L., Chang, C.-T., Lee, H.-H., Zhou, J., Wang, J., Sham, T.-K., & Pong, W.-F. (2011) · ACS Nano · doi:10.1021/nn2015908 · Cited by 328
Cited by
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review
Yang, C., Denno, M. E., Pyakurel, P., & Venton, B. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.049 · Cited by 577
Zhang, X., Zhang, Y.-C., & Ma, L.-X. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.12.073 · Cited by 339
Label-free optical biosensors for food and biological sensor applications
Khansili, N., Rattu, G., & Krishna, P. M. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.004 · Cited by 328
Zhang, W., Zhu, S., Luque, R., Han, S., Hu, L., & Xu, G. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00297d · Cited by 313
Metadata
- Authors
- Yue, H. Y., Huang, S., Chang, J., Heo, C., Yao, F., Adhikari, S., Gunes, F., Liu, L. C., Lee, T. H., Oh, E. S., Li, B., Zhang, J. J., Huy, T. Q., Luan, N. V., & Lee, Y. H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-13
- Volume
- 8
- Issue
- 2
- Pages
- 1639-1646
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2031454914
- Cited by
- 310
- References
- 21
- FWCI
- 19.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ZnO Nanowire Arrays on 3D Hierachical Graphene Foam: Biomarker Detection of Parkinson’s Disease. https://app.cochat.ai/papers/10.1021/nn405961p
- The paper
- Yue, H. Y., Huang, S., Chang, J., Heo, C., Yao, F., Adhikari, S., Gunes, F., Liu, L. C., Lee, T. H., Oh, E. S., Li, B., Zhang, J. J., Huy, T. Q., Luan, N. V., & Lee, Y. H. (2014). ZnO Nanowire Arrays on 3D Hierachical Graphene Foam: Biomarker Detection of Parkinson’s Disease. ACS Nano. https://doi.org/10.1021/nn405961p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.