Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record.

Polyfluorene-Sorted, Carbon Nanotube Array Field-Effect Transistors with Increased Current Density and High On/Off Ratio

Brady, Gerald J., Joo, Yongho, Wu, Meng-Yin, Shea, Matthew J., Gopalan, Padma, Arnold, Michael S.·2014·ACS Nano

Abstract

Challenges in eliminating metallic from semiconducting single-walled carbon nanotubes (SWCNTs) and in controlling their alignment have limited the development of high-performance SWCNT-based field-effect transistors (FETs). We recently pioneered an approach for depositing aligned arrays of ultra-high-purity semiconducting SWCNTs, isolated using polyfluorene derivatives, called dose-controlled floating evaporative self-assembly. Here, we tailor FETs fabricated from these arrays to achieve on-conductance (G(on)) per width and an on-off ratio (G(on)/G(off)) of 261 μS/μm and 2 × 10(5), respectively, for a channel length (L(ch)) of 240 nm and 116 μS/μm and 1 × 10(6), respectively, for an L(ch) of 1 μm. We demonstrate 1400× greater G(on)/G(off) than SWCNT FETs fabricated by other methods, at comparable G(on) per width of ∼250 μS/μm and 30-100× greater G(on) per width at comparable G(on)/G(off) of 10(5)-10(7). The average G(on) per tube reaches 5.7 ± 1.4 μS at a packing density of 35 tubes/μm for L(ch) in the range 160-240 nm, limited by contact resistance. These gains highlight the promise of using ultra-high-purity semiconducting SWCNTs with controlled alignment for next-generation semiconductor electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn5048734

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Brady, G. J., Joo, Y., Wu, M.-Y., Shea, M. J., Gopalan, P., & Arnold, M. S.
Venue
ACS Nano
Published
2014-11-13
Volume
8
Issue
11
Pages
11614-11621
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2320642867
Cited by
162
References
0
FWCI
8.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.