The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Plasmonic Hydrogen Sensing with Nanostructured Metal Hydrides
Open accessAbstract
In this review, we discuss the evolution of localized surface plasmon resonance and surface plasmon resonance hydrogen sensors based on nanostructured metal hydrides, which has accelerated significantly during the past 5 years. We put particular focus on how, conceptually, plasmonic resonances can be used to study metal-hydrogen interactions at the nanoscale, both at the ensemble and at the single-nanoparticle level. Such efforts are motivated by a fundamental interest in understanding the role of nanosizing on metal hydride formation processes in the quest to develop efficient solid-state hydrogen storage materials with fast response times, reasonable thermodynamics, and acceptable long-term stability. Therefore, a brief introduction to the thermodynamics of metal hydride formation is also given. However, plasmonic hydrogen sensors not only are of academic interest as research tool in materials science but also are predicted to find more practical use as all-optical gas detectors in industrial and medical applications, as well as in a future hydrogen economy, where hydrogen is used as a carbon free energy carrier. Therefore, the wide range of different plasmonic hydrogen sensor designs already available is reviewed together with theoretical efforts to understand their fundamentals and optimize their performance in terms of sensitivity. In this context, we also highlight important challenges to be addressed in the future to take plasmonic hydrogen sensors from the laboratory to real applications in devices, including poisoning/deactivation of the active materials, sensor lifetime, and cross-sensitivity toward other gas species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schlapbach, L. (2009) · Nature · doi:10.1038/460809a · Cited by 435
Cited by
Tungsten Oxides for Photocatalysis, Electrochemistry, and Phototherapy
Huang, Z., Song, J., Pan, L., Zhang, X., Wang, L., & Zou, J. (2015) · Advanced Materials · doi:10.1002/adma.201501217 · Cited by 608
Active metamaterials and metadevices: a review
Xiao, S., Wang, T., Liu, T., Zhou, C., Jiang, X., & Zhang, J. (2020) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/abaced · Cited by 429
Hydrogen Storage Materials for Mobile and Stationary Applications: Current State of the Art
Lai, Q., Paskevicius, M., Sheppard, D. A., Buckley, C. E., Thornton, A. W., Hill, M. R., Gu, Q., Mao, J., Huang, Z., Liu, H. K., et al. (2015) · ChemSusChem · doi:10.1002/cssc.201500231 · Cited by 414
Metal–polymer hybrid nanomaterials for plasmonic ultrafast hydrogen detection
Nugroho, F. A. A., Darmadi, I., Cusinato, L., Susarrey-Arce, A., Schreuders, H., Bannenberg, L. J., da Silva Fanta, A. B., Kadkhodazadeh, S., Wagner, J. B., Antosiewicz, T. J., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0325-4 · Cited by 365
Self-citationHybrid Metamaterial Absorber Platform for Sensing of CO 2 Gas at Mid‐IR
Hasan, D., & Lee, C. (2018) · Advanced Science · doi:10.1002/advs.201700581 · Cited by 173
Metadata
- Authors
- Wadell, C., Syrenova, S., & Langhammer, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-08
- Volume
- 8
- Issue
- 12
- Pages
- 11925-11940
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2021021957
- Cited by
- 283
- References
- 1
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasmonic Hydrogen Sensing with Nanostructured Metal Hydrides. https://app.cochat.ai/papers/10.1021/nn505804f
- The paper
- Wadell, C., Syrenova, S., & Langhammer, C. (2014). Plasmonic Hydrogen Sensing with Nanostructured Metal Hydrides. ACS Nano. https://doi.org/10.1021/nn505804f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.